{"product_id":"bently-nevada-3500-92-03-01-cn-3500-92-communication-gateway-module","title":"Bently Nevada 3500\/92-03-01-CN 3500\/92 Communication Gateway Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/92-03-01-CN\u003c\/strong\u003e is an industrial communication module that provides high-speed integration of rack-monitored variables and statuses with process control systems, distributed control systems (DCS), and plant automation networks. The module supports both Ethernet TCP\/IP and serial multi-drop infrastructures (including RS232, RS422, and RS485 physical layers) to manage the transmission of critical machinery data. Beyond plant host interfaces, it enables seamless Ethernet communications with the 3500 Rack Configuration Software and 3500 Data Acquisition Software packages.\u003c\/p\u003e\n\u003cp\u003eBy incorporating an internal network backplane, the \u003cstrong\u003e3500\/92-03-01-CN\u003c\/strong\u003e collects time-stamped measured values, current hardware module statuses, and current alarm event logs directly from adjacent machinery protection cards. The unit features a Configurable Modbus Register Utility to customize information maps transferred via Modicon Modbus (serial) and Modbus\/TCP (Ethernet) protocols. This specific model variant consists of a full-height front processor combined with an Ethernet\/RS232 Modbus I\/O module designed for robust serial-to-network translations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive communication capabilities across all 3500 rack-monitored values, alarm statuses, and hardware operational diagnostics.\u003c\/li\u003e\n\u003cli\u003eConfigurable Modbus Register Utility allows custom-tailored database layouts matching process control architecture profiles.\u003c\/li\u003e\n\u003cli\u003eSupports Modicon Modbus (RTU mode via serial lines) and standard Modbus\/TCP frames over Ethernet networks.\u003c\/li\u003e\n\u003cli\u003eProvides isolated dual-protocol operation for concurrently serving automation hosts and Bently Nevada software utilities.\u003c\/li\u003e\n\u003cli\u003eFront panel diagnostic array featuring a dedicated OK LED for system health and a TX\/RX LED to confirm intra-rack communication traffic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control System (DCS) and Programmable Logic Controller (PLC) machine data streaming.\u003c\/li\u003e\n\u003cli\u003eReal-time remote vibration monitoring and thermal metric aggregation over standard plant infrastructure.\u003c\/li\u003e\n\u003cli\u003eIntegration of turbomachinery protection systems with safety instrumented systems (SIS) and plant historians.\u003c\/li\u003e\n\u003cli\u003eRemote configuration, diagnosis, and acquisition management via centralized server configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/92-03-01-CN\u003c\/strong\u003e configuration corresponds to the following exact build options from the 3500\/92 series database:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/92\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Gateway Module Product Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Module Type: Ethernet\/RS232 Modbus I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMemory Type: Low Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e \/ \u003cstrong\u003e-01\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: CSA\/NRTL\/C (Class I, Division 2, Groups A, B, C, D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 Watts typical with Modbus RS232\/RS422 I\/O Module \/ 5.6 Watts typical with Modbus RS485 I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Collection Rate (Update Time)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 1 second for all modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Link Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mbps, conforms to IEEE 802.3 Ethernet TCP\/IP frame specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Connection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ-45 for 10BASE-T Ethernet cabling topologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Modbus Transmission Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Terminal Unit (RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 Celsius to +65 Celsius (-22 Fahrenheit to +149 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Processor Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.44 kg (0.96 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Processor Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement (Front)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement (Rear)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort \/ Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ-45 Ethernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelephone-jack style terminal enabling 10BASE-T link connection for Modbus\/TCP host polling and software configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS232 Serial DB9 Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 9-pin interface supporting serial Modbus RTU communications directly to host process computers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous green indicator verifying proper internal microprocessing and execution of system runtime logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePulsing communication indicator reflecting dynamic data exchange via the internal high-speed network backplane.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Placement:\u003c\/strong\u003e Install the main processing board in a designated full-height front slot of the 3500 system rack chassis. Align and secure the paired Ethernet\/RS232 Modbus I\/O module in the corresponding rear chassis slot directly opposite the front module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Control:\u003c\/strong\u003e Wear a clean grounding wrist strap (such as part number 04425545) before unboxing or touching the circuit assemblies to avoid exposing internal logic gates to static discharge damages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Segmenting:\u003c\/strong\u003e Use standard 10BASE-T Shielded Category 5 cables equipped with RJ-45 termination blocks for the network segment. Ensure length parameters do not exceed 98 meters (320 feet) without external repeating hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cable Configuration:\u003c\/strong\u003e Maximum recommended physical run metrics for serial interfaces should not surpass 1220 meters (4000 feet) for multi-dropped arrangements when matching RS422 or RS485 communication lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Isolation:\u003c\/strong\u003e Ensure unobstructed cabinet airflow across the top and bottom panels of the rack chassis to verify ambient air properties stay well within the -30 Celsius to +65 Celsius operating baseline.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of the FCC Rules for interference control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 2014\/30\/EU (Standards: EN 61000-6-2 for Industrial Immunity, EN 61000-6-4 for Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU (Standard: EN 61010-1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Directive 2011\/65\/EU compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e Certified under DNV GL classification rules for ships, offshore units, and light craft; certified under ABS Rules for Steel Vessels and Offshore Structures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Standards:\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc and AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 rating at ambient zones matching -20 Celsius to +65 Celsius).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668297544043,"sku":"3500\/92-03-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350092-03-01-CN-vp2qhutukes_fb6a3b4a-fd5d-4a05-8fd1-5a77a8aed83a.jpg?v=1765520446","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-92-03-01-cn-3500-92-communication-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}