{"product_id":"bently-nevada-3500-94-145988-01-vga-display-module","title":"Bently Nevada 3500\/94 145988-01 VGA Display Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/94 145988-01\u003c\/strong\u003e is a high-performance \u003cstrong\u003eVGA Display Module\u003c\/strong\u003e belonging to the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This module is designed to collect, process, and display critical data directly from the system rack, serving as a centralized human-machine interface for plant operators and maintenance engineers.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/94\u003c\/strong\u003e (also designated as \u003cstrong\u003e3500\/94M\u003c\/strong\u003e) displays comprehensive machinery protection metrics, including system event lists, alarm event lists, individual module and channel measurements, and real-time OK or alarm statuses. Utilizing the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e, users can establish up to nine custom display screens organized by machine train groups or custom layout requirements. By default, pre-configured layouts present 1X-filtered vibration measurements in bar graphs alongside proximity transducer gap values. The system supports direct interfaces to 10-inch or 15-inch industrial touch screen displays, multi-rack monitoring via an optional Display Router Box, and extended fiber optic remote connectivity via KVM extenders for secure, long-distance data access across large industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisplays full system event lists, alarm event lists, and comprehensive channel data.\u003c\/li\u003e\n\u003cli\u003eSupports up to nine custom display configurations per module via rack software.\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring and visual indications of alarm and OK status.\u003c\/li\u003e\n\u003cli\u003eMulti-rack capabilities allowing up to four 3500 racks on a single display using a router box.\u003c\/li\u003e\n\u003cli\u003eFront-panel status LEDs indicating system communications and module operation.\u003c\/li\u003e\n\u003cli\u003eFront-port integration providing 24 Vdc power out, VGA signal out, and touch command routing.\u003c\/li\u003e\n\u003cli\u003eCompatibility with hazardous-area certified industrial touch screen hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentralized multi-rack machinery vibration display\u003c\/li\u003e\n\u003cli\u003eLarge steam and gas turbine train status tracking\u003c\/li\u003e\n\u003cli\u003eHigh-speed compressor and pump monitoring stations\u003c\/li\u003e\n\u003cli\u003eRemote operator panels via long-distance KVM extension\u003c\/li\u003e\n\u003cli\u003ePetrochemical and power generation plant localized monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eModel \u0026amp; Main Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e145988-01 (3500\/94 \/ 3500\/94M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e4.6 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eHigh-Speed Network\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eMonitor status, data and values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eRS232 Port (I\/O)\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eTouch controller data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eOK LED\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndicates proper operation of the module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eTX\/RX LED\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eIndicates communications between other system modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eVGA Port (I\/O)\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eAnalog red, green, blue and sync signals to the display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eFront Port\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e24 Vdc Power out, VGA signal out, Touch commands in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e-20 Celsius to 65 Celsius (-22 Fahrenheit to 149 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e-40 Celsius to 85 Celsius (-40 Fahrenheit to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003ePhysical Characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e241.3 mm x 24.4 mm x 241.8 mm (9.5 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e0.73 kg (1.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector\/Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eFront Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eProvides 24 Vdc power output, outputs standard VGA video signal, and receives incoming touchscreen command inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eVGA Port (I\/O Module)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eOutputs analog red, green, blue, and synchronization signals directly to the industrial monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eRS232 Port (I\/O Module)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eFor handling incoming and outgoing touch controller communication and response data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Distance Limits:\u003c\/strong\u003e Standard VGA cables allow the display monitor to be mounted at a maximum distance of 6 m (20 ft) from the 3500 rack or the Display Router Box. Exceeding this limit degrades image quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Distance Remote Options:\u003c\/strong\u003e For remote installations from 10 m to 10 km (33 ft to 6.2 miles), implement a Single-mode Fiber Optic (SM FO) Keyboard Video Monitor (KVM) Extender.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Noise Mitigation:\u003c\/strong\u003e Avoid routing VGA signal lines through highly noisy electronic environments to ensure image resolution and synchronization remain stable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Power Supply:\u003c\/strong\u003e Both 10-inch and 15-inch touch screen displays require independent external power supplies; they cannot be powered solely through the interface port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Isolation:\u003c\/strong\u003e When utilizing the Single-mode Fiber Optic KVM receiver and transmitter, both units must be mounted in a designated safe area or placed inside an engineered, approved explosion-proof enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC Compliance:\u003c\/strong\u003e Complies with part 15 of the FCC Rules (Operation subject to no harmful interference and acceptance of any interference received).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e Directive 2014\/30\/EU; Standards EN 61000-6-2, EN 61000-6-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Directive 2014\/35\/EU; Standards CSA C22.2 61010-1, UL EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Hazardous Area Approvals (Option 01 - North America):\u003c\/strong\u003e Canada: Ex nC [L] IIC T4 Gc (CSA60079-0, -11, -15), Class I, Division 2, Groups A, B, C, D (CSA213). USA: Class I, Zone 2: AEx nC IIC T4 Gc (UL60079-0, -11, -15), Class I, Division 2, Groups A, B, C, D (ISA 12.12.01). Temperature rating T4 @ -20 Celsius \u0026lt;= Ta \u0026lt;= +65 Celsius per control drawing 149243.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Hazardous Area Approvals (Option 02 - ATEX\/IECEx):\u003c\/strong\u003e II 3 G, Ex nA nC ic IIC T4 Gc, T4 @ -20 Celsius \u0026lt;= Ta \u0026lt;= +65 Celsius per control drawing 149243.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvantech 10\" Display (AN-D3510) Approvals:\u003c\/strong\u003e North America Option 01: Ex ic nA IIC T4 (CSA C22.2 60079-0, -11, -15), Class I, Div 2, Groups A, B, C, D T4 (CSA C22.2 213); USA Class I, Div 2, Groups A, B, C, D T4 (ISA 12.12.01), Class I, Zone 2, AEx ic nA IIC T4 (UL60079-0, -11, -15). ATEX\/IECEx Option 02: II 3G Ex ic nA IIC T4 Gc, IP54.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvantech 15\" Display (FPM-8151) Note:\u003c\/strong\u003e Not certified to meet ATEX\/IECEx standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat information can be displayed using this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt displays system event lists, alarm event lists, module and channel operational data, and overall system OK or alarm status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many custom display screens can be configured on the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUp to nine custom screens can be configured using the core rack configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the default pre-configured layouts on the screens?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe first default screen shows a bar graph of 1X-filtered vibration measurements, and the second shows proximity transducer gap values.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan data from multiple monitor racks be aggregated onto one display?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, an optional Display Router Box allows up to four separate racks to share a single display monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the max direct cabling distance between a rack and the display router box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum recommended cabling length is 6 meters or 20 feet due to constraints in the VGA signal standard.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can the display monitor be moved further than 6 meters away from the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA single-mode fiber optic Keyboard Video Monitor extender must be deployed to route signals over longer distances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum achievable distance using fiber optic extenders?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eData can be extended up to 10 kilometers or 6.2 miles without causing any loss in visual display quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the KVM extenders certified for immediate placement in hazardous environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, both the fiber optic transmitter and receiver modules must be situated in safe zones or housed in approved protective enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sizes of industrial touch screen displays are officially supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system supports 10-inch and 15-inch industrial touch screen display formats.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre both the 10-inch and 15-inch display options safe for ATEX zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnly the 10-inch display carries ATEX and IECEx certification, whereas the 15-inch display option does not meet these standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the front panel LEDs show during normal operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OK LED indicates the main display module is operating correctly, while the TX\/RX LED indicates standard intra-rack communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total internal power consumption of the main module card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws a maximum power allocation of 4.6 watts.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519847275,"sku":"145988-01","price":3500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-94-145988-01-vga-display-monitor-ijpyu2p25hi_10a55afc-a9cf-4660-b88b-0f006d61d756.jpg?v=1765440142","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-94-145988-01-vga-display-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}