{"product_id":"bently-nevada-3500-94m-02-00-cn-3500-94m-vga-display-unit","title":"Bently Nevada 3500\/94M-02-00-CN 3500\/94M VGA Display Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/94M-02-00-CN\u003c\/strong\u003e is an industrial VGA display unit designed for the Bently Nevada 3500 Machinery Protection System. It displays comprehensive asset data and status metrics directly from the machine train, including system event lists, alarm event lists, and detailed channel measurements. By integrating the \u003cstrong\u003e3500\/94M-02-00-CN\u003c\/strong\u003e within a 19-inch EIA rack structure, operators gain localized or extended access to critical values such as 1X-filtered vibration levels and proximity transducer gap data.\u003c\/p\u003e\n\u003cp\u003eThe system relies on high-speed network interfaces to pull real-time monitor status and variables from the rack. Configuration of custom viewing environments is fully supported through the 3500 Rack Configuration Software, enabling users to organize operational data into nine distinct screen designs categorized by machine train groupings. This module communicates touch-control data over dedicated RS232 links and transmits analog RGB and sync information to provide steady industrial display feeds.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete visualization of machinery protection system data including system event lists, alarm events, and OK status.\u003c\/li\u003e\n\u003cli\u003eFully programmable configuration via 3500 Rack Configuration Software supporting up to nine custom display layouts.\u003c\/li\u003e\n\u003cli\u003eDedicated front panel indicators including an OK LED for health tracking and a TX\/RX LED indicating communication with other rack modules.\u003c\/li\u003e\n\u003cli\u003eDual hardware framework consisting of a front-mounted full-height VGA monitor control module and a matching rear I\/O module.\u003c\/li\u003e\n\u003cli\u003eFlexible distance routing using standard interfaces up to 6 meters (20 feet) or up to 10 kilometers (6.2 miles) via Single-Mode Fiber Optic KVM extenders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time localized machinery status display in oil and gas refineries.\u003c\/li\u003e\n\u003cli\u003eCentralized turbomachinery monitoring in power generation facilities using multi-rack display routers.\u003c\/li\u003e\n\u003cli\u003eHigh-vibration industrial asset management (pumps, compressors, and fans).\u003c\/li\u003e\n\u003cli\u003eRemote control room safety display configurations spanning up to 10 kilometers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/94M-02-00-CN\u003c\/strong\u003e configuration corresponds to the following verified options from the 3500\/94M product series:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/94M\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVGA Display Monitor System (Includes Front VGA Module \u0026amp; Rear I\/O Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10-inch display, 19-inch EIA rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKVM Extender and Display Router Box Cables: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e \/ \u003cstrong\u003e-00\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eAgency Approvals: None \/ Standard Regional Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.5 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.73 kg (1.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10-inch Display Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e387.4 mm x 248.9 mm x 49.0 mm (15.25 in x 9.8 in x 1.93 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10-inch Display Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 kg (8.78 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Module\/I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 Celsius to 65 Celsius (-4 Fahrenheit to 149 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to 85 Celsius (-40 Fahrenheit to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Input Voltage (10-inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc power supply included (Permissible range 10 Vdc to 28 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Inrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 A @ 24 V (\u0026lt; 500 microseconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Operating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Ingress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP54 dust and water spray protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot (Monitor Module) and 1 full-height rear slot (I\/O Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-speed network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterfaces with the system to acquire monitor statuses, values, and channel variables.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS232 port (I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoutes interactive touch controller commands and data between the module and display panel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVGA port (I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelivers analog red, green, blue, and sync signals to feed the terminal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutbound 24 Vdc power delivery, outbound VGA video stream, and inbound touch data path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Selection:\u003c\/strong\u003e Mount the primary VGA display module into a single full-height front slot of the 3500 chassis. Position the partner I\/O module in the corresponding full-height rear slot directly behind it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Dependencies:\u003c\/strong\u003e Ensure the 3500 rack includes a 3500\/22 Transient Data Interface (TDI) module running firmware revision 1.71 or higher.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Restrictions:\u003c\/strong\u003e Limit standard analog VGA and touch routing paths to a maximum length of 6 meters (20 feet). Lengthy expansions beyond this specification without an active KVM transmitter break signal transmission quality and introduce image degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Sequencing:\u003c\/strong\u003e Verify that input power to the equipment is entirely isolated and switched off before attaching or removing interconnecting cables in industrial bays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Enclosure Requirements:\u003c\/strong\u003e If the 10-inch hardware display face or front bezel is slated to operate in environments where ambient air conditions drop below -20 Celsius, a regulated, heated enclosure must be provided to shield the internal liquid crystal matrix.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 2014\/30\/EU (Standards: EN 61000-6-2, EN 61000-6-4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU (Standards: UL EN 61010-1, CSA C22.2 61010-1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668296790379,"sku":"3500\/94M-02-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-94M-02-00-CN-x1zmo3zncxx_639e563e-0652-4173-95ea-8a77623a82e6.jpg?v=1765520420","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-94m-02-00-cn-3500-94m-vga-display-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}