{"product_id":"bently-nevada-350500-00-01-00-10-05-dynamic-pressure-charge-amplifier-module","title":"Bently Nevada 350500-00-01-00-10-05 Dynamic Pressure Charge Amplifier Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e350500-00-01-00-10-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edynamic pressure charge amplifier from Bently Nevada is designed for high fidelity signal conditioning in demanding industrial pressure measurement systems. It is widely used in turbomachinery testing, combustion analysis, hydraulic systems, and research environments where accurate dynamic pressure conversion is required to ensure stable process control and reduced operational risk.\u003c\/p\u003e\n\u003cp\u003eThis charge amplifier converts low level piezoelectric charge signals into a stable voltage output for downstream monitoring and control systems. It supports high accuracy signal processing for rapidly changing pressure conditions, making it suitable for combustion chambers, engine test benches, and rotating machinery diagnostics. The unit is configured with 16 pC per psi input sensitivity and 100 mV per psi output scaling, ensuring consistent signal integrity across industrial measurement chains. The panel mount design with MIL connector provides secure installation in control cabinets exposed to vibration. The multi agency approval option supports deployment in regulated industrial environments requiring compliance across multiple certification standards.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eInput sensitivity: 16 pC per psi (232 pC per bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eLow pass frequency configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eOutput sensitivity: 100 mV per psi (1.45 V per bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003ePanel mount configuration with MIL connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMulti agency approval package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e350500-00-01-00-10-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDynamic Pressure Charge Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e16 pC per psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV per psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMIL connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.246 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCharge to voltage conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eDynamic pressure monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow power industrial electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of this charge amplifier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt converts piezoelectric charge signals into stable voltage signals for industrial measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this module commonly used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is used in engine testing, combustion analysis, and turbomachinery pressure monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it handle high frequency pressure changes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is designed for dynamic pressure environments with fast signal variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for control cabinet installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The panel mount design supports secure installation in industrial control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eEnsure proper grounding of the amplifier chassis to avoid signal noise in high sensitivity measurement applications.\u003c\/p\u003e\n\u003cp\u003eUse shielded cables for all sensor inputs to maintain signal integrity in electrically noisy industrial environments.\u003c\/p\u003e\n\u003cp\u003eMaintain airflow inside control cabinets to prevent thermal accumulation affecting long term measurement stability.\u003c\/p\u003e\n\u003cp\u003eSeparate signal wiring from power cables to reduce electromagnetic interference in dynamic pressure systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322218347,"sku":"350500-00-01-00-10-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350500-00-01-00-10-05-loxhwldutky_d9c2ed63-4048-4bcc-b27d-2db9ca8c6d73.jpg?v=1765521191","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-350500-00-01-00-10-05-dynamic-pressure-charge-amplifier-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}