{"product_id":"bently-nevada-60m100-00-wind-condition-monitor","title":"Bently Nevada 60M100-00 Wind Condition Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 60M100-00\u003c\/strong\u003e is a \u003cstrong\u003eWind Condition Monitor\u003c\/strong\u003e designed for continuous permanent monitoring of wind turbine generator machine trains. Operating as a compact, robust unit, the \u003cstrong\u003e60M100-00\u003c\/strong\u003e processes dynamic input signals and speed inputs to detect machine defects months in advance of potential failure, supporting condition-based maintenance strategies.\u003c\/p\u003e\n\u003cp\u003eThe unit features up to 12 dynamic input channels and two Keyphasor speed signal inputs. Channels 1 through 10 interface with 2-wire ICP type accelerometers, while channels 11 and 12 can be configured for either 2-wire ICP transducers or 3-wire proximity probes. The \u003cstrong\u003e60M100-00\u003c\/strong\u003e incorporates a 24-bit Sigma-Delta A\/D converter, 40 kHz bandwidth, and integrated digital communication capabilities, transmitting monitored values and statuses via Modbus\/TCP or proprietary Ethernet protocols to process control and automation systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupport for up to 12 dynamic signal input channels and 2 Keyphasor speed inputs.\u003c\/li\u003e\n\u003cli\u003e24-bit Sigma-Delta A\/D conversion with 110 dB dynamic range and 0 to 40 kHz bandwidth.\u003c\/li\u003e\n\u003cli\u003eSignal processing for 150 static variables, high-resolution waveform data, and trendlines.\u003c\/li\u003e\n\u003cli\u003eFive operating modes based on generator power levels (25% to \u0026gt;85% power).\u003c\/li\u003e\n\u003cli\u003eTwo independent 10\/100 BaseT Ethernet ports supporting Modbus\/TCP client\/server modes and Adapt.wind proprietary protocols.\u003c\/li\u003e\n\u003cli\u003eTwo 15-pin DSUB buffered signal output connectors with 550 ohm output impedance.\u003c\/li\u003e\n\u003cli\u003eFront panel LED status indication for Power, OK, Danger, Alert, Keyphasor triggers, and Network Link\/Activity.\u003c\/li\u003e\n\u003cli\u003eInternal historical data storage supporting up to 2 weeks of data under non-alarm conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTower sway monitoring\u003c\/li\u003e\n\u003cli\u003eMain bearing monitoring\u003c\/li\u003e\n\u003cli\u003eMain rotor monitoring\u003c\/li\u003e\n\u003cli\u003eGearbox monitoring (internal bearings and gear meshes)\u003c\/li\u003e\n\u003cli\u003eDebris monitoring\u003c\/li\u003e\n\u003cli\u003eGenerator bearings monitoring\u003c\/li\u003e\n\u003cli\u003eGenerator grounding monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60M100-AA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada Wind Condition Monitor (Monitor Only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (a Baker Hughes business)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60M100-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 Vdc to 36 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 A Max, less than 5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 12 dynamic signals and 2 Keyphasor signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 dB @ fs = 102.4 ksps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal\/Noise Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 dB @ fs = 102.4 ksps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSigma-Delta 24 bits nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDirect pk or rms Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ± 0.5% of full-scale typical, ± 1.1% worst case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRotor, Mesh and Fault Frequencies Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 6.7% typical, ± 9.7% worst case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBearing Frequencies Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 6.7% typical, ± 9.7% worst case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTower Sway Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.16 m\/s2 (0.016 g) typical, ± 0.23 m\/s2 (0.023 g) worst case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKurtosis Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 1% (50 Hz to 10,000 Hz), ± 3% (1 Hz to 49.9 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Electrical Noise Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 1% (50 Hz to 10,000 Hz), ± 3% (1 Hz to 49.9 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrest Factor Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ± 0.5% of full-scale typical, ± 1.1% worst case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Amplitude for Crest\/Skewness\/Kurtosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 m\/s2 (0.06 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Speed Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 120,000 rpm (limited to 2,000 rpm for wind turbines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Speed Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 rpm (1 to 100 rpm), ± 1 rpm (100 to 2000 rpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Output Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNet A: 10\/100 BaseT Network DHCP Port\u003c\/p\u003e\n\u003cp\u003eNet B: 10\/100 BaseT Local Static IP Port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Signal Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 15-pin DSUB connectors (550 ohm output impedance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC (-40 degF to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-45 degC to +85 degC (-49 degF to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing operating and storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePollution Degree 2 (working voltage \u0026lt; 30 Vrms or 60 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mm x 225 mm x 55 mm (5.89 x 8.88 x 2.17 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (3 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - CH 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField wiring connections for 2-wire ICP type accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 11 - CH 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField wiring connections for 2-wire ICP transducers or 3-wire proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKPH 1 - KPH 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField wiring connections for Keyphasor speed sensors (3-wire proximity probes or externally powered speed sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet A (10\/100 BaseT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork DHCP Ethernet port for system communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet B (10\/100 BaseT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal Static IP Ethernet port for system communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Signal Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 15-pin DSUB connectors for diagnostic signal access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal connector for 18 Vdc to 36 Vdc power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Stud\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround connection stud on chassis side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Common Isolation Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch for system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the monitor unit onto a standard DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect an input DC power source supplying between 18 Vdc and 36 Vdc (24 Vdc nominal, rated for at least 1.7 A continuous).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Connect the dedicated chassis ground stud to the earth ground to ensure adequate shielding and noise suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Wiring:\u003c\/strong\u003e Wire accelerometers and proximity probes directly to the terminal block connections labeled CH 1 through CH 12 and Keyphasor inputs KPH 1\/KPH 2 as designated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Integration:\u003c\/strong\u003e Connect Net A to the local network using a standard CAT5 Ethernet cable for DHCP operation, or Net B for direct local static IP connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Wiring:\u003c\/strong\u003e Access raw buffered signals using 15-pin DSUB breakout cables connected to the buffered output ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e EN 61000-6-2, EN 61000-6-4, EMC Directive 2014\/30\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e EN 61010-1, LV Directive 2014\/35\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53718124364139,"sku":"60M100-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/60M100-00_001_1200x1200_21ca5992-7eeb-456e-be84-d11224175f88.jpg?v=1786622450","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-60m100-00-wind-condition-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}