{"product_id":"bently-nevada-84661-99-standard-armored-interconnect-cable","title":"Bently Nevada 84661-99 Standard Armored Interconnect Cable","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e84661-99\u003c\/strong\u003e is a heavy-duty, industrial-grade \u003cstrong\u003estandard armored interconnect cable\u003c\/strong\u003e engineered to maintain safe, uninterrupted signal routes inside severe processing environments. This high-integrity hardware assembly links casing-mounted proximity sensors, accelerometers, or velocity transmitters directly to remote monitor racks, programmable logic controllers (PLCs), or distributed control systems (DCSs). To combat severe electrical noise, the \u003cstrong\u003e84661-99\u003c\/strong\u003e utilizes a 22 AWG twisted, shielded pair architecture wrapped inside a robust aluminum-polyester shielding tape with an integrated drain wire line.\u003c\/p\u003e\n\u003cp\u003eWhat distinguishes this specific variant is its outer layer of stainless steel armor shielding, which provides superior mechanical crush protection, cutting resistance, and physical guarding against abrasive structural contact or accidental pinch points. The assembly comes factory-terminated with a tight-fitting, 2-socket moisture-resistant molded female connector block with a threaded locking ring at one end to establish an airtight environmental seal on the sensor header, and raw bare wire ends on the opposing side for rapid terminal strip landing. The \u003cstrong\u003e-99\u003c\/strong\u003e suffix indicates a precise factory-cut length configuration of exactly 99 feet (approximately 30.1 meters), ensuring stable signal transmission over extended plant layouts without adding capacitive signal distortion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel armored outer wrap providing excellent physical crush guarding and mechanical protection in harsh areas.\u003c\/li\u003e\n\u003cli\u003eHigh-density 2-conductor twisted, shielded pair configuration to block high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-molded moisture-resistant 2-socket female connector establishing a locked ambient seal at the transducer head.\u003c\/li\u003e\n\u003cli\u003eStripped bare wire trailing ends prepared for efficient termination inside local monitor panel terminal strips.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty 22 AWG high-conductivity copper core layout maximizing signal path transmission efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRouting critical casing velocity or vibration signals across exposed open-air industrial structural steel decks.\u003c\/li\u003e\n\u003cli\u003eInterfacing field-mounted vibration transmitters with remote control rooms in heavy-duty mining, oil, or refining operations.\u003c\/li\u003e\n\u003cli\u003eGeneral low-voltage instrumentation link integration across high-vibration balance-of-plant rotating machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661 (Standard Armored Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-99 (Specified length of 99 feet \/ 30.18 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84661-99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Armored Twisted Shielded Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (Approximately 0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull coverage aluminum-polyester shield line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Protection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel flexible protective armor wrap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant molded female connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBare wire ends prepared for terminal strip landing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 300 V RMS operational insulation capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope rated for high-thermal field exposures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft. (30.18 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary Minimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGenerous layout radius required due to flexible stainless steel armor wrap limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard armored field interconnect cable weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded 2-socket female connector with integrated threaded locking ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate bare wire channels for positive, negative, and shield drain lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmored Routing Routes:\u003c\/strong\u003e Secure the armored cable length along structural beams using heavy-duty cable clamps. While the steel armor prevents crush damage, avoid pulling it past sharp metal edges that could tear the outer jacket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Connection Sealing:\u003c\/strong\u003e Align the female terminal connector pins accurately onto the transducer plug. Hand-tighten the threaded coupling ring completely to verify a locked, moisture-resistant environmental barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain generous layout bend loops at all enclosure entry joints. Avoid sharp crimps or tight physical kinks that could deform the stainless steel armor or split the internal core shielding layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Point Grounding:\u003c\/strong\u003e Connect the shield drain wire only at one designated common reference ground point—typically at the monitor panel terminal strip—to prevent creating performance-degrading ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666621821291,"sku":"84661-99","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-99-standard-armored-interconnect-cable-bc1dfu0pzkg_c1ec598a-bbca-4e1c-8e7e-fb4cd2dbb9b1.jpg?v=1765444271","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-84661-99-standard-armored-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}