{"product_id":"bently-nevada-86691-00680-0350-10-00-vibration-probe","title":"Bently Nevada 86691-00680-0350-10-00 Vibration Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-reliability machinery protection systems, the \u003cstrong\u003eBently Nevada 86691-00680-0350-10-00\u003c\/strong\u003e functions as a rugged industrial \u003cstrong\u003evibration probe\u003c\/strong\u003e designed to capture critical static and dynamic shaft measurements. This proximity probe assembly operates on eddy current principles to continuously monitor radial vibration, axial thrust, and keyphasor reference signals on critical rotating assets.\u003c\/p\u003e\n\n\u003cp\u003eBuilt to withstand harsh industrial environments, this sensor probe provides precise distance measurements between the probe tip and the target shaft. By delivering continuous, non-contact displacement monitoring, it assists predictive maintenance systems in detecting rotor instability, misalignment, and bearing wear before catastrophic failure occurs. The probe integrates seamlessly with standard Bently Nevada monitoring racks and Proximitor sensor systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Contact Measurement:\u003c\/strong\u003e Uses eddy current technology for highly repeatable, wear-free displacement and vibration tracking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Robust construction designed to survive exposure to extreme temperatures, chemical splash, and lubricating oils.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachinery Protection Compatibility:\u003c\/strong\u003e Fully compatible with industry-standard Bently Nevada vibration monitors and transmitters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStable Signal Output:\u003c\/strong\u003e Minimized temperature drift ensures highly reliable monitoring across wide operating ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration monitoring.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal and reciprocating compressor monitoring.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty industrial pumps and generator bearings.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft displacement tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e86691-00680-0350-10-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProximity\/Vibration Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy Current (Non-Contact)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal sensor performance and prevent electrical interference, adhere to the following installation practices:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Calibration:\u003c\/strong\u003e Utilize a calibrated voltmeter or calibration fluidic setup to adjust the physical gap distance within the linear range of the Proximitor sensor before locking the mounting thread.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the probe's extension cables through dedicated conduit to isolate low-voltage sensor signals from high-voltage motor or control wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the sensor system shield is grounded at the monitor rack end only to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain the recommended minimum bend radius for coaxial cables during installation to prevent signal degradation or physical conductor stress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310651243,"sku":"86691-00680-0350-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/86691-00680-0350-10-00-kj1yvloprx5_d6527799-f6c3-46ca-95c3-2221eb5b0f1b.jpg?v=1765520844","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-86691-00680-0350-10-00-vibration-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}