{"product_id":"bently-nevada-89477-80-right-angle-interconnect-cable","title":"Bently Nevada 89477-80 Right Angle Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 89477-80\u003c\/strong\u003e is a ruggedized shielded interconnect cable assembly designed to link machinery instrumentation with centralized machinery monitoring systems. This specialized data loop component measures 80 feet (24.0 meters) in total length and is constructed from robust 0.963 mm2 (18 AWG) conductors to ensure stable instrumentation link characteristics. To allow clean signal paths in tight structural envelopes while providing a secure fit in unconditioned, damp operational spaces, the transducer connection side features a factory-integrated, moisture-resistant right-angle female plug, complemented by standardized industrial ring lugs on the monitor termination interface. The multi-conductor infrastructure features a heavy shielding barrier to minimize external ground-loop disruptions and high-frequency noise emissions, protecting vital vibration and condition data trends across demanding industrial thermal ranges.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAssembled with robust internal 0.963 mm2 (18 AWG) shielded instrumentation cables.\u003c\/li\u003e\n\u003cli\u003ePre-terminated with a specialized moisture-resistant right-angle female plug on the transducer path end.\u003c\/li\u003e\n\u003cli\u003eIntegrated heavy-duty ring lugs on the monitoring system panel interface.\u003c\/li\u003e\n\u003cli\u003eEngineered with premium shielding paths to block local unconditioned noise emissions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-integrity instrumentation signal paths connecting field machinery sensors to core asset condition monitors.\u003c\/li\u003e\n\u003cli\u003eDense space terminal routings or unconditioned process zones demanding right-angle moisture-sealed links.\u003c\/li\u003e\n\u003cli\u003eContinuous vibration loop tracks on critical industrial rotating machinery exposed to wide climate spans.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe model code structure for this right-angle interconnect cable assembly follows a standardized length selection system. The part number prefix is paired with a specific two-digit suffix that indicates the total length of the cable in feet.\u003c\/p\u003e\n\u003cp\u003eUse the configuration table below to identify or specify the exact orderable model number based on your system length requirements:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrderable Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length (Feet)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Length (Meters)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ft\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 ft\u003c\/td\u003e\n\u003ctd\u003e3.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 ft\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-17\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 ft\u003c\/td\u003e\n\u003ctd\u003e5.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003ctd\u003e6.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003ctd\u003e7.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ft\u003c\/td\u003e\n\u003ctd\u003e9.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-33\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003ctd\u003e10.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ft\u003c\/td\u003e\n\u003ctd\u003e15.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-80\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 ft\u003c\/td\u003e\n\u003ctd\u003e24.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e89477-99\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 ft\u003c\/td\u003e\n\u003ctd\u003e30.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight Angle Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 ft (24.0 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.963 mm2 (18 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Design Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Connection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant right angle female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Connection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Position\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Interface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant right angle female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLay out the 80-foot instrumentation loop along designated industrial cable conduits, preventing severe sharp mechanical bends or excessive pulling friction.\u003c\/li\u003e\n\u003cli\u003eThread and fully seat the moisture-resistant right-angle female connector onto the transducer head housing terminal to complete the environmental seal.\u003c\/li\u003e\n\u003cli\u003eAnchor the heavy-duty ring lugs securely to the terminal rail blocks inside the monitoring system chassis, establishing firm mechanical retention.\u003c\/li\u003e\n\u003cli\u003eSeparate the sensor communication path from high-voltage primary motor power leads to prevent field noise coupling or transient signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666538983787,"sku":"89477-80","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-80-interconnect-cable-4h2fzgxxi5b_bca57e98-6d9a-4633-a2be-aa944da286d1.jpg?v=1765440447","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-89477-80-right-angle-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}