{"product_id":"bently-nevada-9200-06-05-10-00-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-06-05-10-00 Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-06-05-10-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003evelocity transducer\u003c\/strong\u003e engineered for continuous monitoring or periodic measurements of absolute structural, casing, or bearing housing vibration. Operating via moving-coil technology, this system delivers a voltage output directly proportional to the mechanical vibration velocity without requiring an external power source. The \u003cstrong\u003e9200-06-05-10-00\u003c\/strong\u003e configuration is specifically less sensitive to impact or impulsive excitation compared to solid-state sensors, making it ideal for standard casing velocity applications across critical machinery like turbines, fans, and pumps.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire moving-coil technology design providing an direct voltage output without external power\u003c\/li\u003e\n\u003cli\u003eReduced sensitivity to impact or impulsive excitation compared to solid-state alternatives\u003c\/li\u003e\n\u003cli\u003eSuitable for both continuous machinery protection and periodic portable diagnostics\u003c\/li\u003e\n\u003cli\u003eHigh-grade anodized aluminum casing providing robust resistance to industrial environmental factors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute bearing housing and casing vibration measurement on rotating machinery\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine structural vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePortable test instrument data collection and diagnostics\u003c\/li\u003e\n\u003cli\u003eBalance and misalignment tracking on heavy industrial fans and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Configuration Profile\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle\/Minimum Operating Frequency: 0 ±100, 10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Terminal block top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: Circular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% at +22 Celsius with 25 mm\/s of casing vibration at 100 Hz under 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom 10 Hz to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (Vertical, viewed from driver end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along non-sensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between transducer and 3300\/3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 Celsius to +121 Celsius (-20 Fahrenheit to +250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block top mount (Polyphenylene Sulfide with nickel-plated copper contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.54 mm (3.092 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.40 mm (1.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Out (Signal goes positive with respect to B when case velocity moves toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignments:\u003c\/strong\u003e Ensure the transducer is installed strictly within its specified 0 ±100 vertical boundaries relative to the machine axis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Application:\u003c\/strong\u003e Tighten the M10X1 mounting base option to exactly 5.6 Nm (50 in-lb) during seating to preserve optimal amplitude and frequency response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Fidelity:\u003c\/strong\u003e Verify that structural or rotor vibration paths are faithfully transmitted to the bearing housing or casing location chosen for the transducer installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Countermeasures:\u003c\/strong\u003e Ensure the top-mounted terminal block enclosure is sufficiently protected against dust and moisture ingestion to fit local environmental ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 9200-06-05-10-00 require an external power supply to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this transducer leverages a moving-coil architecture which inherently creates its own voltage signal output proportional to the vibration velocity without external power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operating frequency threshold for this precise configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific unit uses the -06 option, which defines a minimum operating frequency threshold of 10 Hz (600 cpm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the sensor signal cable be handled over long distances?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system supports up to 305 meters of leadwire between the velocity sensor and a 3300 or 3500 series monitor, though you should consult the manual for high-frequency roll-off parameters when using extended lengths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary differences between this moving-coil sensor and solid-state alternatives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMoving-coil sensors display much lower sensitivity to impact or impulsive excitations compared to embedded integration solid-state alternatives, providing specific advantages on designated casing installations.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867712363,"sku":"9200-06-05-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-10-00-velocity-seismoprobe-jzrvpejc0gv_9b3aa907-a1c6-44fd-96f1-814ed8ac1a38.jpg?v=1765449515","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-9200-06-05-10-00-seismoprobe-velocity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}