{"product_id":"bently-nevada-9571-32-standard-interconnect-cable","title":"Bently Nevada 9571-32 Standard Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e9571-32\u003c\/strong\u003e is a rugged, industrial-grade \u003cstrong\u003estandard interconnect cable\u003c\/strong\u003e designed for high-reliability signal transmission within machinery condition monitoring systems. Engineered to link machinery sensors or transmitters directly to asset protection monitors and processing racks, this cable ensures the uncompromised delivery of critical vibration, position, and speed raw waveforms. The model \u003cstrong\u003e9571-32\u003c\/strong\u003e utilizes a premium 22 AWG 2-conductor twisted, shielded pair architecture wrapped in a durable insulation layer to safeguard data integrity against aggressive electromagnetic interference (EMI) and radio frequency interference (RFI) common in plant environments.\u003c\/p\u003e\n\u003cp\u003eThe assembly features a factory-terminated, moisture-resistant 2-socket female connector block at one end to interface securely with field transducers, and standard bare wire terminal lugs at the opposing end for streamlined connection inside local monitor racks or termination blocks. The \u003cstrong\u003e-32\u003c\/strong\u003e suffix denotes a specific physical length of exactly 32 feet (approximately 9.7 meters). This cable is fully rated for continuous industrial operation across wide temperature variations, delivering stable signal dynamics for critical rotating assets without contributing data loss or capacitive distortion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-integrity 2-conductor twisted, shielded pair configuration to block high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-installed 2-socket moisture-resistant female connector providing tight environment sealing at the transducer end.\u003c\/li\u003e\n\u003cli\u003ePre-installed terminal ring lugs at the monitor end for quick, reliable terminal strip mounting.\u003c\/li\u003e\n\u003cli\u003eRugged 22 AWG high-conductivity copper core layout maximizing signal path transmission efficiency.\u003c\/li\u003e\n\u003cli\u003eFlexible, orientation-agnostic construction allowing easy pathing through tightly packed wire tracks and conduits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnecting casing vibration velocity sensors or accelerometers to remote monitor frames.\u003c\/li\u003e\n\u003cli\u003eInterfacing field-mounted vibration transmitters directly with host control system analog cards.\u003c\/li\u003e\n\u003cli\u003eRouting dynamic diagnostic transducer lines through local junction cabinets to centralized monitoring panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571 (Standard Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-32 (Specified length of 32 feet \/ 9.75 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9571-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Twisted Shielded Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG (Approximately 0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull coverage aluminum-polyester shield line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-socket moisture-resistant molded female connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard pre-crimped terminal ring lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 300 V RMS operational insulation capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pull Tension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.2 lbs (17.8 kg) structural limit rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope from -29 to 121 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary Minimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28 in. (57.9 mm) mechanical limitation path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 ft. (9.75 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Compatibility Restriction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot for use inside 21128 Velocity Transducer Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNet weight approximately 0.8 kg (1.76 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded 2-socket female connector with threaded locking mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate positive, negative, and shield drain ring terminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Route Planning:\u003c\/strong\u003e Pull the cable assembly through dedicated low-voltage instrument conduits. Ensure it is path-isolated from high-current motor supply wires to minimize capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer End Threading:\u003c\/strong\u003e Align the 2-socket female connector pins accurately with the sensor output pins. Tighten the connector sleeve to establish a compressed, moisture-resistant environmental seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain a physical path layout radius greater than 2.28 in. (57.9 mm) at all enclosure entry joints to prevent structural core strain or shielding separation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Drain Grounding:\u003c\/strong\u003e Terminate the instrument shield drain wire only at one designated common ground reference point (typically inside the monitor rack terminal block) to avoid generating problematic ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666526957931,"sku":"9571-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-32-cable-yfifvsfafj0_9f55ffc9-d680-4e6b-92ad-ee7e476cf3fd.jpg?v=1765440291","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-9571-32-standard-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}