{"product_id":"bently-nevada-990-05-xx-03-cn-104m6732-01-vibration-transmitter","title":"Bently Nevada 990-05-XX-03-CN 104M6732-01 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e990-05-XX-03-CN\u003c\/strong\u003e (Internal Part Number: \u003cstrong\u003e104M6732-01\u003c\/strong\u003e) is a high-accuracy, loop-powered \u003cstrong\u003e2-wire vibration transmitter\u003c\/strong\u003e engineered to provide continuous, standalone machinery asset protection. This field-rugged industrial instrument integrates the functionality of a proximity sensor conditioner and transmitter into a single unified circuit block, converting raw non-contacting proximity probe inputs directly into an industry-standard 4-20 mA analog current loop output proportional to overall shaft vibration. The \u003cstrong\u003e990-05-XX-03-CN 104M6732-01\u003c\/strong\u003e accepts dynamic electrical signals from a standard proximity probe array and processes raw peak-to-peak displacement, delivering an immediate, linear current stream to local programmable logic controllers (PLCs), distributed control systems (DCSs), or SCADA platforms. Designed specifically with space-restricted and safety-critical machinery skids in mind, it interfaces with external measurement loops without requiring an intermediate Proximitor sensor housing. It features physical terminal integration supporting a 4-20 mA current output loop, separate dynamic voltage output points for portable vibration analyzers, and special hardware certification variants for localized control markets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated 2-wire transmitter design providing a direct 4-20 mA proportional current output path without intermediate signal conditioners.\u003c\/li\u003e\n\u003cli\u003eDynamic voltage output terminal provisioning real-time raw proximity waveforms directly to field analyzers.\u003c\/li\u003e\n\u003cli\u003eRobust electrical isolation and solid-state encapsulation to eliminate electrical noise interference inside tight machine enclosures.\u003c\/li\u003e\n\u003cli\u003eSeamless host system integration linking directly with any control interface featuring standard analog current input blocks.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-reliability vibration tracking across thin fluid-filmed bearing shells and rotating shaft assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous radial vibration and casing displacement tracking on centrifugal air and process gas compressors.\u003c\/li\u003e\n\u003cli\u003eCritical machinery safety loops on high-speed industrial fans, cooling pumps, and fluid-handling blowers.\u003c\/li\u003e\n\u003cli\u003eStandalone balancing and predictive maintenance monitoring across small-scale power generation turbines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990 (2-Wire Vibration Transmitter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-03-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Factory Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104M6732-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Option Suffix Code Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05 (System Full-Scale Range Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-XX (Variable Options Selection Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-03 (Mounting Hardware Base Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-CN (Regional Specific Certification \/ Approval Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-03-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104M6732-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Interface Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop-powered current loop circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC proportional to overall peak-to-peak vibration displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Waveform Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered voltage output terminal for local analyzer plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Power Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC external supply loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contacting proximity transducer probe assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 Option Specific Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Envelope Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03 Mounting Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Assembly Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN Certified Configuration Variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Mechanical Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum housing with integrated terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Core Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-profile compact footprint optimized for high-density side-by-side rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard field transmitter assembly weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Point Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Function Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ \/ Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive DC Loop Voltage Input Supply \/ Signal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- \/ Return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Return \/ Current Loop Signal Output Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF \/ Dynamic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamic Raw Voltage Output Signal Point (For portable vibration meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM \/ Ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Circuit Ground reference terminal line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated connection terminal block input for external proximity probe lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Chassis Mounting:\u003c\/strong\u003e Fix the transmitter block securely onto a clean, unpainted, vibration-isolated instrument panel inside an electrical enclosure. Verify proper physical layout alignment to prevent internal structural stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximity Probe Connection:\u003c\/strong\u003e Direct the primary proximity transducer coaxial lead wire straight into the designated input terminal channel block. Keep the internal signal wires separate from any high-voltage motor electrical conduits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Power Verification:\u003c\/strong\u003e Check the overall loop resistance parameters and source power input ratings before energizing the 4-20 mA current network lines to avoid unexpected component strain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Terminal Shielding:\u003c\/strong\u003e Ensure the dynamic voltage output terminal covers are completely sealed when not hooked up to local portable instruments to keep moisture and dust off the diagnostic contacts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863157611,"sku":"990-05-XX-03-CN 104M6732-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-xx-03-cn-104m6732-01-vibration-transmitter-2p0d2asnnce_24d3e90c-bdb7-4d6a-ae74-4313620d804e.jpg?v=1765449361","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-990-05-xx-03-cn-104m6732-01-vibration-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}