{"product_id":"bently-nevada-991-06-70-01-00-991-thrust-transmitter","title":"Bently Nevada 991-06-70-01-00 991 Thrust Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e991 Thrust Transmitter\u003c\/strong\u003e provides continuous axial shaft position monitoring for rotating machinery protection systems. The transmitter converts proximity probe displacement signals into a proportional 4 to 20 mA output suitable for PLC, DCS, and machinery monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 991-06-70-01-00\u003c\/strong\u003e is configured for a 0.6 mm full-scale measurement range and a 7.0 m transducer system length. The unit supports direct integration with compatible proximity probe systems for thrust position measurement on compressors, pumps, motors, and other critical rotating equipment.\u003c\/p\u003e\n\u003cp\u003eThe transmitter combines signal conditioning and current loop transmission within a compact housing. DIN-rail mounting clips simplify cabinet installation in industrial control panels and OEM machinery skids.\u003c\/p\u003e\n\u003cp\u003eDiagnostic signal access supports maintenance verification and machinery condition analysis during operation. The design is suitable for installations requiring continuous thrust monitoring with standard analog control system interfaces.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-wire loop-powered transmitter\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA output signal\u003c\/li\u003e\n\u003cli\u003e0.6 mm full-scale range\u003c\/li\u003e\n\u003cli\u003e7.0 m system length configuration\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting clips\u003c\/li\u003e\n\u003cli\u003eIntegrated signal conditioning\u003c\/li\u003e\n\u003cli\u003eCompact industrial housing\u003c\/li\u003e\n\u003cli\u003eDiagnostic signal access\u003c\/li\u003e\n\u003cli\u003eSuitable for continuous thrust monitoring\u003c\/li\u003e\n\u003cli\u003eCompatible with machinery protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial pumps\u003c\/li\u003e\n\u003cli\u003eSteam turbines\u003c\/li\u003e\n\u003cli\u003eElectric motors\u003c\/li\u003e\n\u003cli\u003eRotating equipment skids\u003c\/li\u003e\n\u003cli\u003eProcess control systems\u003c\/li\u003e\n\u003cli\u003eTurbomachinery monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial vibration monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003ctd\u003eThrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e0.6 mm full-scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e7.0 metres (23.0 feet) system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required agency approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e991-06-70-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Option\u003c\/td\u003e\n\u003ctd\u003e0.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e7.0 metres (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e53.3 mm x 73.9 mm x 100.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height (without DIN clip)\u003c\/td\u003e\n\u003ctd\u003e42.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Distance (Width x Length)\u003c\/td\u003e\n\u003ctd\u003e63.5 mm x 69.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e5.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the transmitter on a standard 35 mm DIN rail inside a grounded industrial enclosure. Maintain adequate spacing between signal wiring and high-voltage power cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eUse shielded transducer cables and connect shields according to plant grounding practices. Avoid routing probe cables near motor starters, VFD output wiring, or switching power supplies.\u003c\/p\u003e\n\u003cp\u003eVerify proper probe gap adjustment before system commissioning. Incorrect mechanical positioning may affect transmitter scaling and thrust measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eEnsure sufficient ventilation inside the control cabinet when the transmitter operates in elevated ambient temperatures.\u003c\/p\u003e\n\u003cp\u003eInspect DIN-rail retention clips after installation to confirm secure mechanical mounting in high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the transmitter measure?\u003c\/strong\u003e\u003cbr\u003eIt measures axial shaft displacement for thrust position monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output signal does the unit provide?\u003c\/strong\u003e\u003cbr\u003eThe transmitter provides a 4 to 20 mA analog output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the configured measurement range?\u003c\/strong\u003e\u003cbr\u003eThis version uses a 0.6 mm full-scale range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich mounting method is included?\u003c\/strong\u003e\u003cbr\u003eThe unit includes 35 mm DIN-rail mounting clips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the system cable length?\u003c\/strong\u003e\u003cbr\u003eThe configured system length is 7.0 metres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the transmitter connect to a PLC analog input?\u003c\/strong\u003e\u003cbr\u003eYes. The 4 to 20 mA output is suitable for standard PLC and DCS analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the transmitter suitable for compressor monitoring?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used on compressors and other rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the housing support panel installation?\u003c\/strong\u003e\u003cbr\u003eYes. The compact housing supports industrial control cabinet installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of machinery commonly uses this device?\u003c\/strong\u003e\u003cbr\u003ePumps, motors, compressors, and turbines commonly use thrust transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs external signal conditioning required?\u003c\/strong\u003e\u003cbr\u003eNo. Signal conditioning is integrated within the transmitter.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317270379,"sku":"991-06-70-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-06-70-01-00-vibration-transmitter-nubym3e0lah.jpg?v=1765439757","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-991-06-70-01-00-991-thrust-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}