{"product_id":"bently-nevada-am3100t2-z2-iepe-accelerometer","title":"Bently Nevada AM3100T2-Z2 IEPE Accelerometer","description":"\u003ch2\u003eAM3100T2-Z2 Description\u003c\/h2\u003e\n\u003cp\u003eThe AM3100T2-Z2 is an Integrated Electronics Piezo-Electric (IEPE) accelerometer optimized for obtaining high quality vibration signals in harsh industrial environments. Its piezo sensing element provides exceptional dynamic range, frequency range, and linearity, while the integrated amplifier boosts the signal and improves immunity to electrical noise.\u003c\/p\u003e\n\u003cp\u003eThe sensor requires an industry standard constant-current power supply and provides an output voltage proportional to the acceleration signal, allowing interface with a wide variety of condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe AM3100T2-Z2 features a top-exit connector configuration, 100 mV\/g sensitivity, and Zone 2 hazardous-area certification.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged stainless design, corrosion resistant\u003c\/li\u003e\n\u003cli\u003eHermetic seal, case isolated\u003c\/li\u003e\n\u003cli\u003eESD protection\u003c\/li\u003e\n\u003cli\u003eReverse wiring protection\u003c\/li\u003e\n\u003cli\u003eEMI \/ RFI shielded\u003c\/li\u003e\n\u003cli\u003eHazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAble to fit in small spaces\u003c\/li\u003e\n\u003cli\u003eLight weight for walk around programs\u003c\/li\u003e\n\u003cli\u003eCross wiring does not harm sensor\u003c\/li\u003e\n\u003cli\u003ePrevents ground loops in permanent mount applications\u003c\/li\u003e\n\u003cli\u003eCan be hosed down or submersed with proper connector\u003c\/li\u003e\n\u003cli\u003eCan be used in applicable certified hazardous areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eDynamic\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensitivity, ±5% @25°C\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAcceleration range\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e80 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAmplitude nonlinearity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eFrequency response ±10%\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.7-9,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFrequency response ±3 dB\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.4-14,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eResonant frequency\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eTransverse sensitivity, max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e±5% of axial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eTemperature response\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-55°C : -20% \/ +120°C : +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eVoltage source\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e18-30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCurrent regulating diode\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e2-10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eBroadband electrical noise @ 2.5 Hz to 25 kHz\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e500 μg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSpectral electrical noise @ 10 Hz\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e7 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSpectral electrical noise @ 100 Hz\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSpectral electrical noise @ 1000 Hz\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e2 μg\/√Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eOutput Impedance, max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBias output voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGrounding\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eCase isolated, internally shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-55°C to 120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eVibration limit\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e500 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShock limit\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eElectromagnetic sensitivity, equiv g, max\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e70 μg\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSealing\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eHermetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBase strain sensitivity, max\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.0002 g\/μstrain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePhysical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterValue\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensing element design\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePZT ceramic \/ shear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e62 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eCase material\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e316L Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e¼-28 UNF tapped hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eTop exit, 2-pin, MIL-C-5015 style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eRecommended cabling\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eShielded, twisted pair, no longer than 100 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eShell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eGround\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eA\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003ePower \/ Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eB\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFrequency response and spectral noise values are typical.\u003c\/p\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003ch3\u003eMounting Surface Preparation\u003c\/h3\u003e\n\u003cp\u003eInstall the sensor on a clean, flat, and rigid mounting surface. Remove paint, rust, grease, and debris before installation to ensure proper mechanical coupling and accurate vibration transmission.\u003c\/p\u003e\n\u003cp\u003ePoor mounting surfaces may reduce high-frequency response and introduce measurement errors.\u003c\/p\u003e\n\u003ch3\u003eMounting Procedure\u003c\/h3\u003e\n\u003cp\u003eUse the supplied ¼-28 mounting stud for installation.\u003c\/p\u003e\n\u003cp\u003eInstallation recommendations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper thread engagement\u003c\/li\u003e\n\u003cli\u003eTighten the sensor securely\u003c\/li\u003e\n\u003cli\u003eAvoid excessive mounting torque\u003c\/li\u003e\n\u003cli\u003ePrevent sensor base distortion during installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Routing\u003c\/h3\u003e\n\u003cp\u003eUse shielded twisted-pair cable as recommended by the manufacturer.\u003c\/p\u003e\n\u003cp\u003eFor best signal quality:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeep cables away from high-voltage wiring\u003c\/li\u003e\n\u003cli\u003eAvoid routing near VFD output cables and large motors\u003c\/li\u003e\n\u003cli\u003ePrevent sharp cable bends\u003c\/li\u003e\n\u003cli\u003eSecure the cable to reduce movement-induced noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRecommended cable length should not exceed 100 feet.\u003c\/p\u003e\n\u003ch3\u003eConnector Protection\u003c\/h3\u003e\n\u003cp\u003eThe sensor uses a top-exit 2-pin MIL-C-5015 style connector.\u003c\/p\u003e\n\u003cp\u003eIn wet or outdoor environments:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully tighten the connector\u003c\/li\u003e\n\u003cli\u003eUse moisture-resistant cables and connectors\u003c\/li\u003e\n\u003cli\u003eRegularly inspect sealing integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe hermetic sensor body helps protect against moisture ingress when properly installed.\u003c\/p\u003e\n\u003ch3\u003ePower Supply Requirements\u003c\/h3\u003e\n\u003cp\u003eThe AM3100T2-Z2 requires an IEPE constant-current power source.\u003c\/p\u003e\n\u003cp\u003eRequired electrical supply:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage source: 18–30 Vdc\u003c\/li\u003e\n\u003cli\u003eCurrent regulating diode: 2–10 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify compatibility with the monitoring system before commissioning.\u003c\/p\u003e\n\u003ch3\u003eGrounding Practices\u003c\/h3\u003e\n\u003cp\u003eThe sensor is case isolated and internally shielded to help reduce ground loop problems.\u003c\/p\u003e\n\u003cp\u003eRecommended practices:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse single-point grounding\u003c\/li\u003e\n\u003cli\u003eAvoid multiple shield grounding locations\u003c\/li\u003e\n\u003cli\u003eInspect grounding continuity during installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHazardous Area Installation\u003c\/h3\u003e\n\u003cp\u003eThe AM3100T2-Z2 is approved for Zone 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003eInstallation must comply with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall per drawing 117M2767\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEnsure all associated wiring, barriers, and cable glands meet hazardous-area installation requirements.\u003c\/p\u003e\n\u003ch2\u003eCompliance and Certifications\u003c\/h2\u003e\n\u003ch3\u003eEuropean Community Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX Directive 2014\/34\/EU\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eLV Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003eReach Directive 1907\/2006\/EC\u003c\/li\u003e\n\u003cli\u003eROHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN 61326-1\u003c\/li\u003e\n\u003cli\u003eEN 60079-0\u003c\/li\u003e\n\u003cli\u003eEN 60079-15\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHazardous Area Approvals\u003c\/h3\u003e\n\u003ch4\u003eCSA\/NRTL\/C\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Div 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 2, AEx\/Ex nA IIC T4\u003c\/li\u003e\n\u003cli\u003eInstall per drawing 117M2767\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eATEX \/ IECEx\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eII 3G Ex nA nC IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat type of sensor is the AM3100T2-Z2?\u003c\/h3\u003e\n\u003cp\u003eThe AM3100T2-Z2 is an IEPE accelerometer designed for industrial vibration monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eWhat is the sensor sensitivity?\u003c\/h3\u003e\n\u003cp\u003eThe sensor sensitivity is 100 mV\/g (±5% at 25°C).\u003c\/p\u003e\n\u003ch3\u003eWhat is the acceleration measurement range?\u003c\/h3\u003e\n\u003cp\u003eThe sensor supports an acceleration range of 80 g peak.\u003c\/p\u003e\n\u003ch3\u003eWhat frequency range does the sensor support?\u003c\/h3\u003e\n\u003cp\u003eFrequency response specifications are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e±10%: 0.7–9,000 Hz\u003c\/li\u003e\n\u003cli\u003e±3 dB: 0.4–14,000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat power supply is required?\u003c\/h3\u003e\n\u003cp\u003eThe sensor requires:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e18–30 Vdc supply voltage\u003c\/li\u003e\n\u003cli\u003e2–10 mA constant current excitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIs the sensor suitable for hazardous areas?\u003c\/h3\u003e\n\u003cp\u003eYes. The AM3100T2-Z2 is certified for Zone 2 hazardous-area applications.\u003c\/p\u003e\n\u003ch3\u003eWhat connector type does the sensor use?\u003c\/h3\u003e\n\u003cp\u003eThe device uses a top-exit 2-pin MIL-C-5015 style connector.\u003c\/p\u003e\n\u003ch3\u003eIs the sensor case grounded?\u003c\/h3\u003e\n\u003cp\u003eNo. The sensor is case isolated and internally shielded.\u003c\/p\u003e\n\u003ch3\u003eWhat is the operating temperature range?\u003c\/h3\u003e\n\u003cp\u003eThe operating temperature range is -55°C to 120°C.\u003c\/p\u003e\n\u003ch3\u003eCan the sensor be used in wet environments?\u003c\/h3\u003e\n\u003cp\u003eYes. The sensor has a hermetic seal and can operate in wet environments when proper sealed connectors and cables are used.\u003c\/p\u003e\n\u003ch3\u003eWhat mounting thread does the sensor use?\u003c\/h3\u003e\n\u003cp\u003eThe mounting interface is a ¼-28 UNF tapped hole.\u003c\/p\u003e\n\u003ch3\u003eWhat cable type is recommended?\u003c\/h3\u003e\n\u003cp\u003eShielded twisted-pair cable is recommended, with a maximum length of 100 feet.\u003c\/p\u003e\n\u003ch3\u003eDoes the sensor include reverse wiring protection?\u003c\/h3\u003e\n\u003cp\u003eYes. The device includes reverse wiring protection to help prevent damage caused by incorrect wiring.\u003c\/p\u003e\n\u003ch3\u003eIs the sensor resistant to EMI and RFI?\u003c\/h3\u003e\n\u003ch3\u003eYes. The sensor includes EMI\/RFI shielding to improve electrical noise immunity.\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666532561259,"sku":"AM3100T2-Z2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-am3100t2-z2-accelerometer-sensor-fdikhyz1gl3_fd86dddc-70d0-4bf5-b7f2-586e8d47d783.jpg?v=1765440377","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-am3100t2-z2-iepe-accelerometer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}