{"product_id":"bently-nevada-as3100s2-z0-iepe-accelerometer","title":"Bently Nevada AS3100S2-Z0 IEPE Accelerometer","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada AS3100S2-Z0\u003c\/strong\u003e is an Integrated Electronics Piezo-Electric (IEPE) accelerometer designed for vibration monitoring in industrial environments. The sensor provides an output voltage proportional to machine acceleration and interfaces with constant-current powered condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThis accelerometer uses a piezoelectric sensing element with an integrated amplifier to improve signal integrity and reduce susceptibility to electrical noise. The device supports vibration measurement applications requiring wide dynamic range, stable linearity, and extended frequency response characteristics.\u003c\/p\u003e\n\u003cp\u003eThe sensor features a hermetically sealed stainless steel housing with case isolation for reduced ground loop effects in permanently mounted installations. The side-exit connector configuration supports installations where cable routing space is limited.\u003c\/p\u003e\n\u003cp\u003eTypical applications include rotating machinery monitoring, predictive maintenance systems, process plant vibration analysis, compressors, pumps, motors, fans, and general industrial machinery protection systems.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Electronics Piezo-Electric (IEPE) design\u003c\/li\u003e\n\u003cli\u003e100 mV\/g sensitivity\u003c\/li\u003e\n\u003cli\u003eStainless steel housing\u003c\/li\u003e\n\u003cli\u003eHermetic sealing\u003c\/li\u003e\n\u003cli\u003eCase isolated construction\u003c\/li\u003e\n\u003cli\u003eReverse wiring protection\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI shielding\u003c\/li\u003e\n\u003cli\u003eESD protection\u003c\/li\u003e\n\u003cli\u003eSide-exit connector configuration\u003c\/li\u003e\n\u003cli\u003eWide frequency response\u003c\/li\u003e\n\u003cli\u003eCompatible with constant-current power supplies\u003c\/li\u003e\n\u003cli\u003eSuitable for harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePump condition monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor protection systems\u003c\/li\u003e\n\u003cli\u003eMotor vibration analysis\u003c\/li\u003e\n\u003cli\u003eFan monitoring systems\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance programs\u003c\/li\u003e\n\u003cli\u003ePortable vibration data collection\u003c\/li\u003e\n\u003cli\u003ePermanent mounted machinery monitoring\u003c\/li\u003e\n\u003cli\u003eProcess industry rotating equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial asset condition monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eDynamicSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensitivity at 25 degC\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAcceleration Range\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e80 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAmplitude Nonlinearity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e+\/-10%: 1.0-5,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e+\/-3 dB: 0.7-10,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eResonant Frequency\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e22 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eTransverse Sensitivity, Max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e+\/-5% of axial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eTemperature Response at -55 degC\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eTemperature Response at +120 degC\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e+10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectricalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eVoltage Source\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e18-30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCurrent Regulating Diode\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e2-10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eBroadband Electrical Noise at 2.5 Hz to 25 kHz\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e700 ug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSpectral Electrical Noise at 10 Hz\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e10 ug\/sqrtHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSpectral Electrical Noise at 100 Hz\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5 ug\/sqrtHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSpectral Electrical Noise at 1000 Hz\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e5 ug\/sqrtHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eOutput Impedance, Max\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eBias Output Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eGrounding\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eCase isolated, internally shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eEnvironmentalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-50 degC to 120 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eVibration Limit\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e500 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShock Limit\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eElectromagnetic Sensitivity, Equivalent g, Max\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e70 ug\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSealing\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eHermetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eBase Strain Sensitivity, Max\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.002 g\/ustrain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003ePhysicalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSensing Element Design\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePZT ceramic \/ shear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e145 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eCase Material\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1\/4-28 captive hex head screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eConnector\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eSide exit, 2-pin, MIL-C-5015 style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eRecommended Cabling\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eShielded twisted pair, maximum 100 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eShell\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eGround\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eA\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003ePower\/Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eB\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003eUse shielded twisted-pair cabling to minimize electromagnetic interference in high-noise industrial environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper grounding practices to avoid unwanted ground loop conditions during permanent installation.\u003c\/p\u003e\n\u003cp\u003eInstall the accelerometer on a clean and rigid mounting surface to maintain vibration signal accuracy.\u003c\/p\u003e\n\u003cp\u003eVerify connector orientation before energizing the sensor to prevent incorrect wiring conditions.\u003c\/p\u003e\n\u003cp\u003eAvoid routing sensor cables alongside high-voltage motor cables or variable frequency drive output wiring.\u003c\/p\u003e\n\u003cp\u003eUse appropriate moisture protection methods when the sensor is installed in washdown or outdoor environments.\u003c\/p\u003e\n\u003cp\u003eConfirm mounting torque and thread engagement before commissioning the monitoring system.\u003c\/p\u003e\n\u003cp\u003eInspect cable shielding continuity during maintenance intervals to maintain signal quality.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of sensor technology is used in this accelerometer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit uses Integrated Electronics Piezo-Electric sensing technology with a PZT ceramic shear element.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor requires a constant-current IEPE power source between 18 and 30 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the sensitivity rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensitivity is 100 mV\/g at 25 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the sensor operate in wet environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hermetically sealed housing supports operation in moisture-prone industrial environments when proper connectors are used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the housing electrically isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The case is isolated and internally shielded.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connector style is used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device uses a side-exit 2-pin MIL-C-5015 style connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum recommended cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe recommended cable length is up to 100 feet using shielded twisted-pair cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting thread is provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor uses a 1\/4-28 captive hex head mounting screw.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the sensor be used for permanent monitoring systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is suitable for permanently mounted vibration monitoring installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe operating range is -50 degC to 120 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes reverse wiring damage the sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor includes reverse wiring protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat vibration range can the device measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe accelerometer supports measurement up to 80 g peak.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat industrial systems can interface with this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor interfaces with condition monitoring and machinery protection systems supporting IEPE inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs EMI\/RFI shielding included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The sensor includes EMI\/RFI shielding to reduce electrical interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572702059,"sku":"AS3100S2-Z0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-as3100s2-z0-sensor-proximity-probe-cable-oyteqcgpfjb_6e0be704-f697-48dd-8542-c7456ac13275.jpg?v=1765440867","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-as3100s2-z0-iepe-accelerometer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}