{"product_id":"cx1010-n060-beckhoff-system-interface-10-100-mbit-s-ethernet-module","title":"CX1010-N060 BECKHOFF System Interface 10\/100 Mbit\/s Ethernet Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1010-N060 (CX1010N060)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated Ethernet system interface designed to expand the communication capabilities of the CX1010 Embedded PC series. This module provides a high-performance 10\/100 Mbit\/s network connection via a standard RJ45 port, serving as a critical bridge for integrating the controller into local area networks (LANs) or connecting to higher-level IT infrastructures. Engineered for reliability in industrial environments such as automated manufacturing cells and building control systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1010-N060\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables seamless data exchange, remote programming, and visualization. Its compact 19 mm form factor allows for efficient modular expansion, ensuring that system designers can add network connectivity without significantly increasing the hardware footprint.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the CX1010-N060 is designed for \"plug-and-play\" integration with the CX system bus. It draws its power directly from the system bus via the connected CX1100-xxxx power supply modules, eliminating the need for external power wiring. The module supports standard Ethernet protocols and is optimized for use with Category 5 (Cat. 5) cabling. A key configuration constraint is that this module is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot combinable with the CX1100-0004\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply unit, a vital consideration for system compatibility and electrical engineering. The interface is housed in a robust IP20-rated enclosure and maintains high levels of EMC immunity, ensuring stable communication even in environments with significant electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCX1010-N060\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x Ethernet (10\/100 Mbit\/s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x RJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 m (Cat. 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVia system bus (CX1100-xxxx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 mm x 100 mm x 51 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +85 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eapprox. 80 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot compatible with CX1100-0004\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CX1010-N060 be used to create a redundant network ring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the CX1010-N060 provides a single Ethernet port intended for point-to-point or switch-based network integration. For network redundancy or ring topologies, specialized EtherCAT or Ethernet redundancy modules from the Beckhoff catalog would be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is there a 20-meter cable length restriction listed for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 20-meter limit is a specified parameter to ensure maximum signal integrity and timing determinism within the CX1010 system architecture using Cat. 5 cabling. While standard Ethernet often allows for longer runs, adhering to this 20-meter limit ensures the module meets its stated EMC and performance ratings in industrial settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require software drivers to be recognized by TwinCAT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CX1010-N060 is automatically recognized by the TwinCAT System Manager as part of the CX hardware configuration. Once connected to the system bus, the Ethernet port can be configured within the operating system (Windows CE or Windows XP Embedded) for TCP\/IP communication.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility Check:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore installation, verify the power supply module in use. The CX1010-N060 is strictly\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincompatible with the CX1100-0004\u003c\/strong\u003e. Using these components together can lead to system bus errors or hardware malfunctions. Ensure your configuration utilizes CX1100-0001, -0002, or -0003 units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling Best Practices:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse only high-quality, shielded Cat. 5 (or higher) Ethernet cables. Although the connection is a standard RJ45, the shield of the cable should be properly grounded through the RJ45 housing to the CX system's ground potential to mitigate the effects of high-frequency industrial noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is designed for 35 mm DIN rail mounting as part of the CX assembly. Ensure the side-mounted PC104-like system bus connectors are clean and properly aligned before snapping the module into place. The double slot and key connection system must be fully engaged to maintain electrical continuity across the system bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106656444779,"sku":"CX1010-N060","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx1010-n060-gih1mr3brcc.png?v=1776244115","url":"https:\/\/www.plcprotech.com\/products\/cx1010-n060-beckhoff-system-interface-10-100-mbit-s-ethernet-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}