{"product_id":"danfoss-060g1369-pressure-transmitter","title":"Danfoss 060G1369 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060G1369\u003c\/strong\u003e is a high-precision pressure transmitter designed for rigorous industrial monitoring and process control applications. Utilizing a current-based output signal (4 - 20 mA), this device ensures reliable signal transmission over long distances, making it an ideal choice for complex plant environments where electromagnetic immunity is critical. Built for endurance, the transmitter operates flawlessly in extreme thermal conditions—ranging from -40 deg C to 100 deg C—and is protected by an IP65-rated enclosure. It serves as a vital feedback component in hydraulic systems, industrial cooling loops, and automated process lines, effectively minimizing system downtime through accurate, repeatable pressure sensing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e060G1369\u003c\/strong\u003e is engineered for straightforward integration into standard industrial architectures, emphasizing ease of installation and operational longevity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e The transmitter outputs a standard 4 - 20 mA current signal, which inherently allows for easy detection of open-circuit or short-circuit failures—a key safety feature in automated control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Robustness:\u003c\/strong\u003e The unit features a G 1\/4 (EN 837) pressure connection with a 27 mm hexagonal interface, ensuring a secure and leak-proof fit in standard piping systems. It is capable of withstanding overload pressures up to 60 bar, providing a significant safety margin against pressure spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connectivity:\u003c\/strong\u003e The transmitter is equipped with an angular Pg 11 connector, facilitating a secure and weather-resistant termination. Pin 1 serves as the positive supply, while Pin 2 acts as the common, conforming to standard industry wiring practices for current-loop sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e060G1369\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Conn.\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 (EN 837)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overload\u003c\/td\u003e\n\u003ctd\u003e60 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Max)\u003c\/td\u003e\n\u003ctd\u003e1.0 % FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is a 4 - 20 mA output preferred over a voltage output for this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCurrent signals (4 - 20 mA) are significantly more resistant to electromagnetic interference and voltage drops across long cable runs compared to voltage-based signals (e.g., 0 - 10 V). This makes them the industry standard for reliable feedback in expansive industrial facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 060G1369 require field calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this unit is factory-calibrated. It does not feature manual zero or span adjustments, which ensures long-term stability and prevents unauthorized or accidental drift of the calibration settings during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this transmitter suitable for outdoor use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith an IP65 enclosure rating, the transmitter is protected against dust and low-pressure water jets. While it is suitable for many outdoor industrial environments, it should be protected from direct, prolonged exposure to severe weather or extreme sunlight to maintain the integrity of the seals and connector.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Torque:\u003c\/strong\u003e Use the 27 mm hexagonal fitting to tighten the pressure connection. Ensure that compatible sealing materials are used for the G 1\/4 thread to prevent leaks, but avoid over-tightening, which can distort the sensor body and degrade measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e Use shielded, twisted-pair cabling for the 4 - 20 mA loop. Terminate the shield at the control panel ground to ensure effective noise immunity. Since this is a current-loop device, ensure the power supply voltage at the transmitter is sufficient to overcome the loop resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClipping Levels:\u003c\/strong\u003e Note the factory-set clipping levels (3.6 mA low \/ 22.4 mA high). These levels are designed to indicate signal out-of-range conditions, allowing control systems to instantly identify if the sensor or cable has failed.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102406893931,"sku":"060G1369","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1369-30fcmxnukej.png?v=1776136915","url":"https:\/\/www.plcprotech.com\/products\/danfoss-060g1369-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}