{"product_id":"danfoss-060g3831-mbs-3000-pressure-transmitter","title":"Danfoss 060G3831 MBS 3000 Pressure Transmitter","description":"\u003ch3\u003eFunctional Profile and Industrial Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G3831 (060G3831)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty industrial pressure transmitter belonging to the renowned Danfoss MBS 3000 series. Engineered to deliver dependable pressure monitoring across severe industrial environments, this instrument is highly optimized for hydraulic systems, water utilities, pneumatic distribution lines, and general mechanical engineering processes.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G3831\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasures a relative (gauge) pressure range from 0 to 4 bar, converting physical force into a stable, linear 0 to 10 VDC voltage output signal.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-51 citation-end-51\"\u003eConstructed with an acid-resistant stainless steel enclosure (AISI 316L) and fully welded wetted parts, the transmitter eliminates internal sealing rings to safeguard against fluid leakage.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis robust structural barrier maintains tight control loop integrity and significantly prevents localized process fluid loss in hazardous, high-vibration applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eOperational Features and Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-50\"\u003e\u003c\/span\u003e\u003cstrong\u003eMBS 3000:\u003c\/strong\u003e\u003cspan class=\"citation-50 citation-end-50\"\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the core compact, general-purpose heavy-duty industrial pressure transmitter platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the calibrated measuring span of 0 to 4 bar (0 to 58 psi).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e\u003cspan class=\"citation-49 citation-end-49\"\u003e\u003cspan\u003e \u003c\/span\u003eSets the measurement reference type to Gauge (Relative pressure measured against current atmospheric pressure).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-48\"\u003e\u003c\/span\u003e\u003cstrong\u003e5:\u003c\/strong\u003e\u003cspan class=\"citation-48 citation-end-48\"\u003e\u003cspan\u003e \u003c\/span\u003eDefines the scaled analog output electronic circuit as a 0 to 10 V high-impedance voltage signal.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDocumented Technical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000-1615-1 (060G3831)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmitter Subtype\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Pressure Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 4 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Output Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngular plug connector Pg 9 (EN 175301-803 Form A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 to 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Overload Pressure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCombined Accuracy Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e0.5% FS (Typical) \/ \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e1.0% FS (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material Base\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Protection Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65 (Fulfilled with matching mating plug attached)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComplete Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations and Logistics FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary electrical supply restrictions for a 0 to 10 V output loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-47 citation-end-47\"\u003eUnlike 4 to 20 mA loop-powered current transmitters that operate on lower minimum voltages, the 0 to 10 V voltage variant of the 060G3831 requires a stable excitation input supply voltage between 15 and 32 VDC.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDropping the supply below 15 VDC will clip the high-end output voltage tracking capability, leading to measurement saturation before the physical 4 bar threshold is achieved.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific field benefits does the fully welded wetted cavity provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter uses a laser-welded diaphragm configuration fabricated from AISI 316L stainless steel. Eliminating internal rubber O-rings or synthetic elastomeric gaskets removes typical mechanical degradation points, allowing long-term chemical compatibility with aggressive oils, gases, and water-glycol mixtures without risk of seal crystallization or chemical blowouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the system log a 1.5 kg shipping weight for a 0.15 kg compact sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.5 kg specification encompasses heavy-duty distribution packaging. Since industrial pressure cells contain precise piezoresistive element layers and digital temperature compensation chips, the component is wrapped in static-dissipative material, nested inside molded corrugated cells, and boxed with dedicated installation calibration certs to endure international shipping lines.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCritical Field Installation and Termination Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-46\"\u003e\u003c\/span\u003e\u003cstrong\u003eElectrical Plug Alignment and IP65 Preservation:\u003c\/strong\u003e\u003cspan class=\"citation-46 citation-end-46\"\u003e\u003cspan\u003e \u003c\/span\u003eConnect the instrument via the integrated EN 175301-803 Form A angular connector.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the rubber sealing profile gasket is aligned completely square between the plug body and the transmitter terminal face prior to tightening the central retention screw. Improper alignment or incomplete tightening drops the ingress barrier below IP65, risking fluid tracking failures inside the housing.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-45\"\u003e\u003c\/span\u003e\u003cstrong\u003eMechanical Torque and Thread Seal Standards:\u003c\/strong\u003e\u003cspan class=\"citation-45 citation-end-45\"\u003e\u003cspan\u003e \u003c\/span\u003eThread the pressure connection cleanly into the mating port using a standard 27 mm hex wrench.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eApply a maximum tightening torque appropriate for G 1\/4 industrial port seals to avoid structural threads cross-threading. Do not apply rotational forces directly to the upper cylindrical body housing, as doing so can tear the internal wire bonds away from the terminal header pins.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Temperature and Condensation Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compensated temperature range spans from 0 to 80 deg C, while the physical wetted medium can operate safely from -40 to 85 deg C. If the field deployment zone is subjected to freezing process media or rapid ambient temperature transitions, trace-heat or insulate the sensing line impulse piping to prevent liquid freeze-ups from cracking the internal pressure diaphragm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102412628331,"sku":"060G3831","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g3831-3ewkfkgtgwg.png?v=1776136943","url":"https:\/\/www.plcprotech.com\/products\/danfoss-060g3831-mbs-3000-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}