{"product_id":"danfoss-060l313066-kps80-temperature-control","title":"Danfoss 060L313066 KPS80 Temperature Control","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 060L313066\u003c\/strong\u003e is a \u003cstrong\u003eKPS80 series temperature control\u003c\/strong\u003e unit engineered for robust monitoring and regulation in demanding industrial environments. This \u003cstrong\u003etemperature switch\u003c\/strong\u003e features an adjustable differential and is equipped with a \u003cstrong\u003e5000 mm capillary tube\u003c\/strong\u003e, providing flexibility for remote sensing applications. Designed for high reliability, the unit utilizes an \u003cstrong\u003eadsorption charge\u003c\/strong\u003e and includes an \u003cstrong\u003eSPDT gold contact\u003c\/strong\u003e configuration, making it suitable for low-current control circuits as well as standard switching operations. The housing is protected with \u003cstrong\u003earmoring\u003c\/strong\u003e and includes a metal cable gland with a Pg 13.5 screwed cable entry for secure electrical connection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: KPS80 Temperature Control\u003c\/li\u003e\n\u003cli\u003eSensing Range: 70 to 120 degC\u003c\/li\u003e\n\u003cli\u003eCapillary Tube Length: 5000 mm\u003c\/li\u003e\n\u003cli\u003eContact Configuration: SPDT Gold\u003c\/li\u003e\n\u003cli\u003eEnclosure Protection: Armoring included\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: Screwed cable entry (Pg 13.5)\u003c\/li\u003e\n\u003cli\u003eConnection Type: M 18 x 1.5 for pocket or hose\u003c\/li\u003e\n\u003cli\u003eCharge Type: Adsorption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial boilers and heat exchangers\u003c\/li\u003e\n\u003cli\u003eMarine cooling and heating systems\u003c\/li\u003e\n\u003cli\u003eProcess plant temperature monitoring\u003c\/li\u003e\n\u003cli\u003eHydraulic power units\u003c\/li\u003e\n\u003cli\u003eCompressor temperature regulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e060L313066\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e70 to 120 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapillary Tube Length\u003c\/td\u003e\n\u003ctd\u003e5000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Type\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating (AC1)\u003c\/td\u003e\n\u003ctd\u003e10 A, 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating (AC3)\u003c\/td\u003e\n\u003ctd\u003e6 A, 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating (AC15)\u003c\/td\u003e\n\u003ctd\u003e4 A, 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating (DC13)\u003c\/td\u003e\n\u003ctd\u003e12 W, 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold Contact Range\u003c\/td\u003e\n\u003ctd\u003e1 to 30 mA, 5 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the sensing element is installed in a location representative of the process temperature. Secure the capillary tube to prevent mechanical damage or excessive vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e The M 18 x 1.5 connection is designed for use with a thermowell (pocket) or hose to ensure accurate temperature transfer and environmental sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entry:\u003c\/strong\u003e Utilize the provided Pg 13.5 metal cable gland to maintain the integrity of the electrical connection against dust and moisture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Adjust the temperature setting and differential according to the specific requirements of the process loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Limits:\u003c\/strong\u003e Ensure the ambient temperature of the control housing remains within the -40 degC to 70 degC range. Note that the unit can withstand 80 degC for a maximum of 120 minutes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102306689387,"sku":"060L313066","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060l313066-g2udui5b3tj.png?v=1776136950","url":"https:\/\/www.plcprotech.com\/products\/danfoss-060l313066-kps80-temperature-control","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}