{"product_id":"danfoss-061b100466-pressure-switch","title":"Danfoss 061B100466 Pressure Switch","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 061B100466\u003c\/strong\u003e is a robust \u003cstrong\u003epressure switch\u003c\/strong\u003e designed for precise monitoring and control of pressure levels in industrial systems. Engineered with a reliable bellows pressure sensing element, this device ensures consistent performance across a defined pressure range. It is suitable for a wide variety of hydraulic and pneumatic applications where reliable automated switching is required.\u003c\/p\u003e\n\u003cp\u003eThe unit features a G-type pressure connection and a Pg 11 electrical connection size, allowing for standardized integration into control cabinets and field installations. With an enclosure rating of IP65, this \u003cstrong\u003epressure switch\u003c\/strong\u003e provides high resistance against dust and moisture, making it suitable for demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReliable bellows-based pressure sensing mechanism\u003c\/li\u003e\n\u003cli\u003eSetting range: -0.20 to 1.00 bar\u003c\/li\u003e\n\u003cli\u003ePe pressure setting range capacity up to 15.0 bar\u003c\/li\u003e\n\u003cli\u003eIP65 ingress protection rating\u003c\/li\u003e\n\u003cli\u003eStandardized G-type pressure connection\u003c\/li\u003e\n\u003cli\u003ePg 11 electrical connection interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial hydraulic and pneumatic pressure monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor and pump control systems\u003c\/li\u003e\n\u003cli\u003ePressure regulation in cooling and heating circuits\u003c\/li\u003e\n\u003cli\u003eProcess automation and safety interlock systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e061B100466\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePressure switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure sensing element\u003c\/td\u003e\n\u003ctd\u003eBellows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Range\u003c\/td\u003e\n\u003ctd\u003e-0.20 to 1.00 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Operating Pressure (Pe)\u003c\/td\u003e\n\u003ctd\u003e15.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure connection type\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection size\u003c\/td\u003e\n\u003ctd\u003ePg 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the device is mounted in a location free from excessive vibration to maintain accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Connection:\u003c\/strong\u003e Verify that the G-type connection is properly sealed to prevent leaks; use appropriate sealing materials compatible with the media.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Wiring:\u003c\/strong\u003e Ensure the Pg 11 cable gland is tightened correctly to maintain the IP65 enclosure integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Adjust the pressure settings within the specified range of -0.20 to 1.00 bar according to the specific requirements of the process loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically inspect the bellows and electrical connections for signs of wear, corrosion, or debris buildup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102306853227,"sku":"061B100466","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/061b100466-whlfc11q2kv.png?v=1776136963","url":"https:\/\/www.plcprotech.com\/products\/danfoss-061b100466-pressure-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}