{"product_id":"danfoss-084g2211-pressure-transmitter-emp-series","title":"Danfoss 084G2211 Pressure Transmitter EMP Series","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 084G2211 (084G2211)\u003c\/strong\u003e is a high-precision pressure transmitter tailored for demanding industrial monitoring applications. As part of the EMP series, this transmitter is designed to provide stable, reliable pressure feedback in hydraulic power units, water distribution systems, and general process control loops. By delivering a consistent 4-20 mA output, the \u003cstrong\u003e084G2211\u003c\/strong\u003e ensures seamless integration with PLC and DCS architectures, playing a vital role in maintaining system precision and reducing unplanned downtime in essential industrial machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis transmitter utilizes a sophisticated piezoresistive sensing element that provides a typical accuracy of 0.5 percent of the full scale. The unit is housed in a robust IP65-rated enclosure, ensuring internal electronics remain shielded from particulate ingress and low-pressure liquid splashes. The pressure connection is configured as a G 3\/8 male port conforming to the EN 837 standard, facilitating secure mounting in industrial-grade pressure gauges and piping systems. Electrical interfacing is performed through a Pg 13.5 terminal block, providing a secure and vibration-resistant connection point for long-term operational stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e084G2211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eDenmark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0 to 16 bar (0 to 232.06 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Typical)\u003c\/td\u003e\n\u003ctd\u003e0.5 % FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Connection\u003c\/td\u003e\n\u003ctd\u003eG 3\/8 Male (EN 837)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 084G2211 suitable for use in vibrating environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EMP series is designed to handle standard industrial vibration levels. For applications with high-frequency mechanical shock, it is recommended to install the transmitter using flexible capillary lines to isolate the sensor from the vibration source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 3.6 mA low clipping level?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3.6 mA threshold acts as a diagnostic indicator. If the transmitter output drops to this level, it signals to the control system that the measured pressure is below the calibrated range or that a circuit fault is present, allowing for immediate corrective action.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the transmitter require periodic recalibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 084G2211 is factory-calibrated for high repeatability. While not strictly required for most applications, an annual verification against a calibrated reference gauge is recommended if the system is subject to high-precision regulatory requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit withstand high temperature media?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe media temperature is rated up to 70 deg C. In applications involving steam or hot oil, use a cooling tower or capillary tube to ensure the temperature at the sensing element remains within this threshold to avoid signal drift.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines and Safety Measures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connections:\u003c\/strong\u003e Observe the P(+) and N(-) polarities during wiring at the terminal block. Ensure the Pg 13.5 cable gland is tightened to the recommended torque to maintain the IP65 seal and prevent wire strain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Port Installation:\u003c\/strong\u003e The G 3\/8 male connection (EN 837) requires a clean, flat-sealing surface. Use a compatible washer or thread sealant to prevent leaks under the maximum overload pressure of 32 bar. Avoid applying torque to the sensor housing itself during mounting; always use the wrench flat on the fitting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Limits:\u003c\/strong\u003e To prevent electronic degradation and premature failure, do not mount the transmitter in locations where ambient temperatures exceed 70 deg C. Provide adequate clearance around the terminal block to allow for future maintenance and signal diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102409384299,"sku":"084G2211","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/084g2211-fhrr1i5bvtk.png?v=1776136991","url":"https:\/\/www.plcprotech.com\/products\/danfoss-084g2211-pressure-transmitter-emp-series","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}