{"product_id":"danfoss-131b0149-fc-302p3k0t5e20h2xgc-vlt-automationdrive-3-0-kw-inverter","title":"Danfoss 131B0149 FC-302P3K0T5E20H2XGC VLT AutomationDrive 3.0 kW Inverter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B0149 (FC-302P3K0T5E20H2XGC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust VLT AutomationDrive FC 302 series frequency inverter, precision-engineered for 3.0 kW (4.0 HP) industrial motor control. Built for high-performance automation, this drive provides sophisticated speed and torque regulation for applications including conveyor systems, pumps, and specialized industrial processing machinery. By integrating advanced control algorithms, the unit optimizes energy consumption and minimizes mechanical stress on connected motor components, significantly reducing the likelihood of unexpected hardware failure and maintaining consistent operational output.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis drive is configured for three-phase operation across a 380-500 V mains voltage range and is housed in an IP20-rated enclosure, designed for integration into standard industrial electrical cabinets. The drive includes a factory-installed RFI filter (H2) to ensure compliance with relevant electromagnetic compatibility standards in industrial zones. To maximize reliability in diverse factory conditions, the internal printed circuit boards (PCBs) feature a high-grade protective coating. Local parameterization and system status monitoring are streamlined via the included Graphical Local Control Panel (LCP), which provides intuitive access to advanced diagnostic and configuration features.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131B0149\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kW (4.0 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMains Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380-500 VAC (Three-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRFI Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH2 (Industrial Class)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrake Chopper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphical LCP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCB Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated (Class C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the coated PCB important for this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" coating on the PCB acts as a barrier against corrosive atmospheric elements, dust, and moisture. This is essential for maintaining long-term reliability in industrial facilities where ambient air quality might otherwise cause oxidation or circuit shorts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive include dynamic braking capability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model (X designation) does not include an internal brake chopper. If your application requires high-torque deceleration or dynamic braking, an external brake module must be integrated into the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for residential network environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the H2 RFI filter is optimized for industrial network categories. For installations in residential or light commercial areas where stricter EMC standards apply, additional filtering or alternative configurations may be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the unit be mounted outside of an electrical cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP20 rating indicates that the drive is not protected against solid objects larger than 12.5 mm or liquid ingress. It must be installed within a properly rated electrical enclosure that provides adequate protection against the factory floor environment.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConvective Cooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe drive relies on vertical convective airflow for thermal management. Ensure a minimum clearance of 100 mm above and below the unit. Do not place heat-sensitive control wiring or plastic components directly in the exhaust path of the drive's cooling fan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Shielding Practices:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent high-frequency noise from affecting control loops or PLCs, motor cables must be shielded. Terminate the shield at the drive's entry point using a 360-degree conductive metal clamp to ensure a low-impedance path to ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegularly verify the tightness of all power terminals. Over time, mechanical vibration can loosen connections; ensure that all mains and motor output terminals are torqued according to the manufacturer's specifications to prevent arc tracking and terminal melting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102411874667,"sku":"131B0149","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131b0149-x1jftrukvqb.png?v=1776136999","url":"https:\/\/www.plcprotech.com\/products\/danfoss-131b0149-fc-302p3k0t5e20h2xgc-vlt-automationdrive-3-0-kw-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}