{"product_id":"danfoss-131b0150-fc-302p4k0t5e20h2xgc-automationdrive","title":"Danfoss 131B0150 FC-302P4K0T5E20H2XGC AutomationDrive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 131B0150 (FC-302P4K0T5E20H2XGC)\u003c\/strong\u003e is a highly reliable VLT AutomationDrive FC 302, precision-engineered for advanced motor control in industrial automation. This 4.0 kW (5.5 HP) drive is designed to optimize the performance of pumps, fans, and high-dynamic machinery, providing superior speed and torque regulation. By minimizing mechanical strain on driven components and maximizing energy efficiency, the \u003cstrong\u003e131B0150\u003c\/strong\u003e serves as a vital tool for engineers focused on reducing operational expenditures and maintaining maximum system uptime in modern manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e131B0150\u003c\/strong\u003e is optimized for high-performance automation tasks, offering a balance of robust hardware and intuitive control features.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Architecture:\u003c\/strong\u003e This model is designed for three-phase 380 - 500 VAC supply systems, with a compact IP20-rated enclosure tailored for efficient mounting within ventilated electrical control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Control:\u003c\/strong\u003e The integrated Graphical Local Control Panel (LCP) provides an intuitive interface for real-time parameter monitoring, quick setup, and advanced diagnostics, significantly reducing commissioning time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC \u0026amp; Protection:\u003c\/strong\u003e Equipped with an H2-class integrated RFI filter, this drive maintains strict electromagnetic compliance in sensitive industrial areas. Furthermore, the internal PCBs are conformal coated (C), providing hardened protection against humidity, dust, and corrosive vapors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking Logic:\u003c\/strong\u003e This configuration (X) does not include an internal brake chopper, making it an optimized solution for constant-load applications where regenerative energy dissipation is not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-302P4K0T5E20H2XGC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e4.0 kW \/ 5.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e380 - 500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhases\u003c\/td\u003e\n\u003ctd\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCP Type\u003c\/td\u003e\n\u003ctd\u003eGraphical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Graphical LCP on this model detachable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Graphical LCP is removable and can be mounted on the front of an electrical cabinet using an optional remote mounting kit, allowing operators to monitor the drive without accessing the cabinet interior.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Coated PCB improve long-term reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conformal coating acts as a barrier against atmospheric contaminants such as moisture and industrial pollutants. This prevents trace-to-trace corrosion and short circuits, which are common failure modes for electronics in non-climate-controlled factory environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended cabinet ventilation for this 4.0 kW drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the drive is efficient, heat dissipation must be managed. Ensure at least 100 mm of clearance above and below the drive to facilitate airflow through the heatsink. If the total heat load of your cabinet is high, calculate the forced-air requirements to keep the ambient temperature below 45 deg C.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e To fully utilize the integrated H2 RFI filter, always use shielded motor cables. Terminate the shield at both the drive and the motor using 360-degree conductive clamps to provide a low-impedance path for high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStartup Verification:\u003c\/strong\u003e Utilize the LCP \"Quick Menu\" to perform a motor auto-tune before applying a full process load. This function allows the drive to identify the motor's specific electrical characteristics, ensuring high-accuracy speed control and optimized torque response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Protocol:\u003c\/strong\u003e Periodically inspect the cooling fins for dust or debris. In industrial environments, a buildup of particulates can restrict airflow and lead to thermal derating. Use dry, compressed air if necessary to ensure the heatsink remains clean.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102408335723,"sku":"131B0150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131b0150-5fdwqkipfkb.png?v=1776137000","url":"https:\/\/www.plcprotech.com\/products\/danfoss-131b0150-fc-302p4k0t5e20h2xgc-automationdrive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}