{"product_id":"danfoss-132f0014-fc-051p2k2t2e20h3bxcxxxsxxx-vlt-micro-drive","title":"Danfoss 132F0014 FC-051P2K2T2E20H3BXCXXXSXXX VLT Micro Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 132F0014 (FC-051P2K2T2E20H3BXCXXXSXXX)\u003c\/strong\u003e VLT Micro Drive is a precision-engineered frequency converter optimized for low-voltage industrial applications. It serves as a vital component in power-sensitive environments such as conveyor systems, machine tools, and process ventilation, where maintaining continuous uptime is critical. By employing advanced VVC+ flux control, this 2.2 kW drive ensures high motor torque stability and exceptional energy efficiency, significantly reducing mechanical wear on driven equipment. Its compact chassis design allows for high-density installation in limited-space control cabinets, providing a reliable, long-term solution for demanding 200-240 VAC power infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e132F0014\u003c\/strong\u003e model string identifies a 2.2 kW (3.0 HP) drive optimized for 200-240 VAC three-phase supply voltage. The \"P2K2\" designation signifies its power capacity, while the \"T2\" identifies the voltage class. This unit is housed in an IP20 chassis suitable for protected environments. It includes an integrated \"H3\" RFI filter for Class A1\/B (C1) electromagnetic compliance, ensuring minimal interference with surrounding electronic instrumentation. The hardware features a factory-fitted internal brake chopper for dynamic braking requirements, and the internal PCB is treated with a conformal coating (\"C\") to enhance durability against humidity and atmospheric contaminants typical in industrial processing zones.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e132F0014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eVLT Micro Drive FC-051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2.2 kW \/ 3.0 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e9.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eMains Voltage\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e200 - 240 VAC (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eEnclosure Class\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003ePCB Coating\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eCoated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e-10 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e19.4 cm x 9 cm x 23.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for single-phase motor control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific model (T2 designation) is designed strictly for three-phase motor applications. Connecting it to a single-phase motor will lead to operational faults and potential hardware failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 132F0014 include a built-in display for parameter monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific unit does not ship with a Local Control Panel (LCP). Monitoring and parameter modification must be conducted via a detachable LCP or through serial communication using external configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the unit handle high-humidity environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the \"C\" suffix indicates the internal printed circuit board is conformal coated, providing a robust barrier against corrosion in humid or mildly aggressive industrial atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum frequency output of this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit can deliver up to 200 Hz in VVC+ mode for standard applications and up to 400 Hz when utilizing U\/f control mode for high-speed motor operations.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Thermal Management:\u003c\/strong\u003e Given the power density of this 2.2 kW unit, ensure the drive is mounted vertically on a flat, heat-conductive surface. Maintain at least 100 mm of clearance above and below the drive to facilitate natural airflow; if ambient temperatures exceed 40 deg C, forced ventilation within the cabinet is mandatory to prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection and Shielding:\u003c\/strong\u003e To comply with electromagnetic compatibility standards, use double-screened motor cables. The cable shield must be clamped 360 degrees to the drive's earth terminal using the provided metal brackets to ensure low-impedance high-frequency grounding, which effectively prevents RFI leakage into the control network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Protocol:\u003c\/strong\u003e Always isolate the main power source before performing any terminal connections. Due to the storage of energy in the DC link capacitors, wait a minimum of 4 minutes after power-off before opening the cover or touching the internal terminals to ensure the voltage has bled off to a safe level.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102411546987,"sku":"132F0014","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132f0014-zfedqkvh5an.png?v=1776137027","url":"https:\/\/www.plcprotech.com\/products\/danfoss-132f0014-fc-051p2k2t2e20h3bxcxxxsxxx-vlt-micro-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}