{"product_id":"danfoss-132l6115-ic2-30-frequency-converter-air-cooled","title":"Danfoss 132L6115 iC2-30 Frequency Converter Air Cooled","description":"\u003cp\u003eThe \u003cstrong\u003eDanfoss 132L6115\u003c\/strong\u003e is an air-cooled \u003cstrong\u003eIC2-30FA1N02-09A6E20F0+ACXX\u003c\/strong\u003e frequency converter designed for variable speed control of AC motors via a single-phase mains supply. The device modulates the frequency and voltage output to regulate motor performance, processing input power within a specified voltage range and delivering a continuous current output to the connected load without integrated dynamic braking capabilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cp\u003eThe frequency converter operates on a single-phase AC mains supply to drive three-phase induction or permanent magnet motors. It utilizes an integrated C1 category EMC filter to minimize high-frequency electromagnetic interference along the power lines. Cooling is achieved via forced air convection across internal heat sinks, and the physical housing conforms to an open-type chassis rating, requiring installation within a protective enclosure to prevent environmental contamination.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e132L6115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eIC2-30FA1N02-09A6E20F0+ACXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eiC2-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eAir cooled (Convection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eMains Input Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eSingle-phase (1N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e200 - 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eRated Current Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e9.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eEnclosure Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIP20 \/ Open type (E20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eEMC Filter Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eC1 category (F0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eNone integrated (+ACXX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eGross Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe complete model code IC2-30FA1N02-09A6E20F0+ACXX decomposes into the following specific functional block modifiers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC2-30:\u003c\/strong\u003e Identifies the iC2-30 product series platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFA:\u003c\/strong\u003e Designates the air-cooled frequency converter configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1N:\u003c\/strong\u003e Specifies single-phase input mains compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02:\u003c\/strong\u003e Indicates an operational mains voltage window of 200 - 240 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-09A6:\u003c\/strong\u003e Sets the maximum continuous nominal current rating to 9.6 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE20:\u003c\/strong\u003e Denotes an IP20 protection class \/ open-type mechanical construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF0:\u003c\/strong\u003e Implies the integration of a C1 category radio frequency interference (RFI) filter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+ACXX:\u003c\/strong\u003e Confirms the omission of an internal brake chopper circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCyclic Data Exchange:\u003c\/strong\u003e Ensure any connected industrial communication interfaces or fieldbus links are mapped with appropriate data words matching the device firmware profile to prevent cyclic data timeouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e The device must be mounted vertically to optimize internal air flow channels. Do not obstruct the intake or exhaust vents located at the top and bottom of the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBraking Constraints:\u003c\/strong\u003e Because this variant lacks an integrated brake chopper (+ACXX), overvoltage tripping may occur during aggressive deceleration phases. Deceleration ramps must be programmed with sufficient duration to accommodate regenerated energy back into the DC bus within safe operational thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a low-impedance high-frequency electrical ground connection from the frequency converter chassis to the central cabinet enclosure backplate. Use a short, braided copper grounding strap for optimal EMC performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Motor cables must be fully shielded. Strip the shield back only at the termination points and use 360-degree grounding clamps to secure the cable shield directly to the drive decoupling plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing and Separation:\u003c\/strong\u003e Maintain a minimum separation distance of 200 mm between control\/signal cables and high-power mains\/motor cables to prevent capacitive coupling. Cross power and signal lines at 90-degree angles if intersection is unavoidable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Adhere to the cable manufacturer's specification for minimum bend radius—typically 10 times the outer cable diameter for fixed installations—to prevent insulation breakdown and shielding degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Integrity:\u003c\/strong\u003e Verify all power terminal connections are torqued to specified nominal limits to prevent localized heating and contact degradation. Ensure the IP20 chassis is shielded from conductive dust or liquid dripping inside the final enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102411710827,"sku":"132L6115","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132l6115-ysnz1jipktx.png?v=1776137042","url":"https:\/\/www.plcprotech.com\/products\/danfoss-132l6115-ic2-30-frequency-converter-air-cooled","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}