{"product_id":"danfoss-132l6118-ic2-30fa3n04-03a7e20f4-acxx-ic2-30-frequency-converter","title":"Danfoss 132L6118 IC2-30FA3N04-03A7E20F4+ACXX iC2-30 Frequency Converter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 132L6118 (IC2-30FA3N04-03A7E20F4+ACXX)\u003c\/strong\u003e iC2-30 Frequency Converter is a high-performance, air-cooled drive engineered for demanding motor control applications. This unit supports a power output of 1.5 kW and is optimized for three-phase 380-480 VAC operations, making it a critical component in automated manufacturing, fluid management, and precision mechanical systems. By ensuring smooth motor acceleration and precise torque regulation, this drive effectively mitigates mechanical stress and reduces unexpected equipment failure, thereby maximizing uptime in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis specific unit, \u003cstrong\u003e132L6118\u003c\/strong\u003e, belongs to the iC2-30 series and features a robust hardware architecture tailored for cabinet-mounted integration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eiC2-30 Series\u003c\/strong\u003e: Designed for versatile, general-purpose industrial tasks requiring high reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System\u003c\/strong\u003e: Air-cooled design to ensure efficient heat dissipation during continuous duty cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Input\u003c\/strong\u003e: Three-phase architecture supporting 380-480 VAC, suitable for standard industrial power grids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Handling\u003c\/strong\u003e: Rated for a continuous output current of 3.7 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Standards\u003c\/strong\u003e: Enclosed in an IP20\/Open type housing for indoor installation within protection-rated electrical cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Filtering\u003c\/strong\u003e: Equipped with an F4 category filter, ensuring compliance with C4 electromagnetic compatibility standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e: This unit is configured without an integrated brake chopper, ideal for standard speed-control applications that do not require regenerative braking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC2-30FA3N04-03A7E20F4+ACXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e1.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e380 - 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e3.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Category\u003c\/td\u003e\n\u003ctd\u003eC4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Brake\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.055 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Danfoss 132L6118 compatible with systems requiring high-frequency braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific part number is configured without an integrated brake chopper (+ACXX), which limits its use in applications requiring rapid deceleration or regenerative braking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the C4 category rating imply for this frequency converter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F4 (C4 category) designation indicates that the drive is designed for use in industrial areas and must be installed with specific EMC precautions to manage electromagnetic interference in environments where other sensitive equipment may be present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be mounted outside of an electrical cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this unit carries an IP20 rating, which indicates it is an open-type device requiring the protection and safety barriers provided by a control cabinet.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control:\u003c\/strong\u003e Due to the air-cooled design, ensure that the installation cabinet is equipped with adequate air filtration and exhaust ventilation. Operating this drive in environments with high dust or conductive particulate matter without a sealed cabinet will lead to premature failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Clearance:\u003c\/strong\u003e Maintain a minimum vertical spacing of 150 mm between the drive and other components to allow for unobstructed cooling airflow. Do not install heat-sensitive components directly above the air exhaust vent of the drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connectivity:\u003c\/strong\u003e Always utilize shielded cabling for motor connections to minimize interference. The cable shield must be grounded at both the motor terminal box and the drive cable entry point using 360-degree clamps to maintain the integrity of the C4 EMC category.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102381564267,"sku":"132L6118","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132l6118-g2cagnf5535.png?v=1776137045","url":"https:\/\/www.plcprotech.com\/products\/danfoss-132l6118-ic2-30fa3n04-03a7e20f4-acxx-ic2-30-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}