{"product_id":"danfoss-134f2973-vlt-automationdrive-fc-360-1-1-kw-frequency-converter","title":"Danfoss 134F2973 VLT AutomationDrive FC 360 1.1 kW Frequency Converter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e134F2973 (FC-360H1K1T4E20H2BXCDXXSXXXXAXBX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance frequency converter from the VLT AutomationDrive FC 360 series, specifically optimized for high-overload industrial applications. Rated for 1.1 kW (1.5 HP), this drive provides precise torque and speed control for machinery requiring robust handling of high-starting loads, such as mixers, extruders, and conveyors. By leveraging advanced internal control loops, the unit enhances energy efficiency and protects mechanical drive trains from peak-load stress, significantly extending the service life of critical production assets in demanding manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis drive is engineered for reliable operation on 380-480 VAC three-phase networks and is housed in a compact IP20\/chassis enclosure, designed for integration into climate-controlled electrical panels. The unit includes an integrated brake chopper (B) for applications requiring dynamic deceleration and a load-sharing (D) option for energy-efficient multi-drive configurations. To ensure durability against industrial contaminants, the internal printed circuit boards (PCBs) feature a protective Class C coating. For network compliance, the integrated Class A2 RFI filter effectively suppresses electromagnetic emissions, allowing for seamless integration into industrial power grids.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e134F2973 (FC-360)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1 kW (1.5 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Overload (H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMains Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380-480 VAC (Three-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRFI Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass A2 (H2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrake Chopper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded (B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCB Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated (Class C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.54 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary benefits of the \"High Overload\" (H) rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe high-overload rating indicates that the drive is specifically built to handle heavy start-up currents and intermittent peak torques required by demanding applications like crushers or heavy-duty conveyors, without triggering thermal protection trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model include a local display?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific configuration (X) is provided without a display or blind cover, designed for applications where the drive is controlled remotely via a fieldbus or an external HMI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the Loadsharing (D) option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe loadsharing option allows multiple drives on a common DC bus to share energy, particularly beneficial in systems where one drive is generating power during braking while another requires power during acceleration, resulting in significant energy savings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for corrosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the inclusion of coated PCBs (Class C) provides a vital layer of protection against corrosive gases and moisture, making this drive suitable for use in environments where standard unprotected electronics would otherwise degrade rapidly.\u003c\/p\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Operational Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC 360 drive must be mounted vertically to facilitate convective cooling through the heatsink. Maintain a minimum clearance of 100 mm above and below the chassis. Avoid installing the drive in locations where it will be exposed to exhaust air from other high-heat components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain compliance with EMC standards, ensure motor cables are shielded and terminated using 360-degree clamps at the drive's entry point. Keeping motor cables separated from control and signal wiring is essential to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways verify terminal screw tightness during commissioning. High-vibration environments can cause power and control connections to loosen over time; use a calibrated torque tool to ensure all cable connections meet the manufacturer's specified values to prevent resistive heating at the terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102411809131,"sku":"134F2973","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/134f2973-fir4gej5c0p.png?v=1776137052","url":"https:\/\/www.plcprotech.com\/products\/danfoss-134f2973-vlt-automationdrive-fc-360-1-1-kw-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}