{"product_id":"danfoss-aks-33-060g2112-pressure-transmitter-4-20-ma","title":"DANFOSS AKS 33 060G2112 Pressure Transmitter 4-20 mA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2112 (060G2112)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered pressure transmitter within the Danfoss AKS 33 series, specifically designed for industrial refrigeration and air conditioning applications. This sensor converts measured pressure into a robust 4-20 mA current output, ensuring high signal integrity over long cable runs in electrically noisy environments. Optimized for reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2112\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a sealed gauge pressure reference and is capable of sustaining overload pressures up to 33 bar. It is a critical component in systems requiring accurate head pressure control or suction pressure monitoring, such as large-scale chillers and commercial cold storage. By providing real-time data to PLC or DCS systems, this transmitter helps maintain optimal system efficiency and prevents critical equipment failures due to overpressure conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe AKS 33 hardware platform is built to withstand the rigors of industrial mechanical rooms while maintaining high metrological performance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensing Technology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a highly stable piezo-resistive sensor coupled with a stainless steel diaphragm, providing excellent resistance to vibrations and thermal cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecialized Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry is factory-calibrated within a compensated temperature range of -30 to 40 deg C, specifically targeting refrigeration cycles to eliminate measurement drift caused by cold-start conditions or ambient shifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an EN 175301-803-A angular connector (DIN plug), providing a secure, IP65-rated connection that simplifies field installation and sensor replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe laser-welded stainless steel body ensures compatibility with common refrigerants and prevents internal moisture ingress, which is essential for low-temperature operating environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G2112\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Group\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSensors (AKS 33)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Reference\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealed Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Overload Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33 bar (479 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompensated Temp. Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 40 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 175301-803-A (Angular Connector)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.157 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 4-20 mA current signal benefit long-distance wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe current signal used by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2112\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis inherently resistant to electromagnetic interference (EMI) and voltage drops across long cables. Unlike voltage signals, the 4-20 mA loop maintains its accuracy over several hundred meters, which is vital for large industrial facilities where the transmitter and controller are far apart.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat medium can be measured with the 060G2112?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis transmitter is compatible with a wide range of media including air, water, and common refrigerants (including ammonia in specific configurations). Its stainless steel construction ensures durability; however, always confirm chemical compatibility for non-standard industrial fluids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the sensor protected against pressure spikes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G2112\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for an overload pressure of 33 bar, frequent high-frequency pressure pulsations can cause mechanical fatigue. It is recommended to use a damping orifice if the sensor is located near a compressor discharge port.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure long-term stability, avoid mounting the transmitter directly onto high-vibration surfaces like compressor heads. Use a short length of capillary tubing to remote-mount the sensor on a stable bracket, which also acts as a thermal buffer for extremely hot or cold media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMoisture Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent condensate from entering the electrical housing, the cable should always enter the angular connector from below. Create a \"drip loop\" in the cable so that moisture gravity-drains away from the transmitter seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque and Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the transmitter into a pressure port, apply sealant only to the threads and not the front face of the sensor. Tighten the unit using the integral hex nut; never apply torque to the upper housing or the electrical connector to avoid damaging the internal electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418133355,"sku":"060G2112","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g2112-z2qqwcgmvlz.png?v=1776136934","url":"https:\/\/www.plcprotech.com\/products\/danfoss-aks-33-060g2112-pressure-transmitter-4-20-ma","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}