{"product_id":"danfoss-fc-101p7k5t4e20-vlt-hvac-basic-drive-7-5-kw","title":"DANFOSS FC-101P7K5T4E20 VLT HVAC Basic Drive 7.5 KW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P7K5T4E20 (FC101P7K5T4E20)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency variable frequency drive from the Danfoss VLT HVAC Basic Drive series, specifically engineered to optimize the performance of fans, pumps, and compressors in building automation systems. Delivering a rated shaft output of 7.5 kW (10.0 HP), this drive is designed to minimize energy consumption and reduce operational costs in heating, ventilation, and air conditioning applications. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P7K5T4E20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a robust IP20 enclosure and integrated H4 class RFI filtering, ensuring reliable operation in commercial environments. With built-in HVAC-specific functions like \"Fire Mode\" for emergency smoke extraction and a specialized PI controller for precise flow regulation, this drive provides essential motor control with an industry-leading efficiency rating of up to 98.5%.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FC 101 series focuses on streamlined integration and industrial durability for HVAC infrastructure:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVVC plus Control Technology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmploys Danfoss’s proprietary Voltage Vector Control to ensure high motor performance and efficiency, maintaining stable torque and smooth operation even at low speeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated RFI Filtering (H4):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a built-in RFI filter to minimize electromagnetic interference, ensuring compliance with commercial building standards and protecting sensitive peripheral electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for continuous operation at 40 deg C with the capability to operate at 50 deg C ambient temperature (with derating), ensuring system reliability in mechanical rooms with limited cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC Software Suite:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes specialized functions such as \"Flying Start\" to catch spinning fans, \"Sleep Mode\" for energy savings during periods of low demand, and \"Fire Mode\" for life-safety overrides.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Optimizer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically adjusts the output voltage to the actual motor load, significantly reducing energy losses and acoustic motor noise during partial load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-101P7K5T4E20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT HVAC Basic Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW \/ 10.0 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 to 480 VAC (3-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 A (at 40 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current (Derated)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.0 A (at 50 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEfficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98.5% (Best Case)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (H4 RFI Filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Cable Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 mm2 (6 AWG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Fire Mode\" function in the FC-101P7K5T4E20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen \"Fire Mode\" is activated, the drive prioritizes continuous motor operation over internal protection protocols. It will ignore most non-critical alarms and trip conditions to ensure that smoke extraction fans or essential pumps continue to run for as long as possible during an emergency situation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the cooling requirements for side-by-side mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP20 enclosure is designed for cabinet mounting. While side-by-side installation is possible, you must ensure sufficient vertical clearance (typically 100 mm) above and below the drive to facilitate natural convection. If the ambient temperature in the cabinet exceeds 40 deg C, the drive will automatically derate its output current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive require an external controller for pressure regulation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P7K5T4E20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a built-in PI controller. By connecting a pressure or flow sensor directly to the drive’s analog inputs, the unit can manage its own speed to maintain a specific setpoint, simplifying the overall control architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shielding and EMC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure the H4 RFI filter functions correctly, use shielded motor cables and ensure the shield is properly grounded at both the drive and motor ends. Use the provided metal decoupling plate to achieve 360-degree grounding of the cable shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtect the drive against mains transients and short circuits using the recommended semiconductor fuses or a thermal-magnetic circuit breaker. Proper fusing is essential to protect the internal DC link and input bridge from catastrophic failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IP20 rating means the drive is not protected against moisture or conductive dust. Always install the unit in a clean, dry, and ventilated control cabinet. If installed in a harsh environment, ensure the cabinet provides the necessary ingress protection (IP54 or higher).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102417379691,"sku":"FC101P7K5T4E20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc101p7k5t4e20-spqycwkp1ua.png?v=1776137412","url":"https:\/\/www.plcprotech.com\/products\/danfoss-fc-101p7k5t4e20-vlt-hvac-basic-drive-7-5-kw","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}