{"product_id":"danfoss-fc-302p15kt5e20h2xgc-vlt-automationdrive-15-kw-inverter","title":"Danfoss FC-302P15KT5E20H2XGC VLT AutomationDrive 15 kW Inverter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P15KT5E20H2XGC (FC-302P15KT5E20H2XGC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT AutomationDrive FC 302 series frequency inverter designed for demanding industrial automation tasks. Rated for 15 kW (20 HP) applications, this drive provides precise speed and torque control for complex machinery in sectors such as manufacturing, material handling, and process automation. By utilizing advanced control algorithms, the unit enhances system energy efficiency, reduces mechanical wear on motors and gearboxes, and offers robust protection against unplanned downtime, ensuring consistent operational throughput.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration features an IP20 enclosure, making it suitable for installation within climate-controlled electrical cabinets. The drive operates on 380-500 V three-phase power and includes a Graphical Local Control Panel (LCP) for intuitive parameterization and status monitoring. To ensure longevity in harsh industrial environments, the internal printed circuit boards (PCBs) are fully coated, protecting the sensitive electronic components from corrosive gases, moisture, and dust buildup. The unit meets EN 55011 Class A2 and IEC 61800-3 Category 3 standards for electromagnetic compatibility, providing reliable operation in standard industrial networks without requiring additional external EMC filters.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-302P15KT5E20H2XGC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 kW (20 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMains Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380-500 VAC (Three-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRFI Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH2 (Category C3\/A2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrake Chopper\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphical LCP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCB Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated (Class C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.57 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the coated PCB?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" coating on the PCB provides a robust protective layer against aggressive industrial environments. It prevents oxidation and short circuits caused by conductive dust or corrosive atmospheric elements, extending the drive's operational life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for applications requiring braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model (X designation) does not include an integrated brake chopper. If your application requires high-torque deceleration or dynamic braking, an external brake module will be necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between H2 and other filter options?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe H2 filter designation means the drive meets industrial EMC category C3\/A2 standards internally. It is designed for use in industrial areas and is generally not suitable for residential networks without further filtering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in a dusty, non-climate-controlled environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP20 rating means the drive is not protected against dust or moisture ingress. It must be installed inside a dedicated electrical enclosure that maintains the required IP rating for the specific factory floor conditions.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC 302 drive generates significant heat during operation. Always maintain a vertical mounting orientation and ensure a clearance of at least 100 mm above and below the unit to allow for unimpeded convective airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure compliance with IEC 61800-3, always use shielded motor cables. Connect the cable shield to the drive’s metallic mounting plate using a 360-degree clamp at the cable entry to prevent high-frequency interference from radiating into nearby control signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways use a calibrated torque wrench for power and control terminal connections. Loose terminals are a frequent cause of overheating and premature drive failure in high-load 15 kW applications; verify terminal tightness during the initial commissioning phase and at scheduled maintenance intervals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102411940203,"sku":"131F8140","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131f8140-4t2mdw2qqwo.png?v=1776137008","url":"https:\/\/www.plcprotech.com\/products\/danfoss-fc-302p15kt5e20h2xgc-vlt-automationdrive-15-kw-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}