{"product_id":"delta-dvp32eh00r2-l-eh3-series-high-performance-plc","title":"DELTA DVP32EH00R2-L EH3 Series High-Performance PLC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP32EH00R2-L (DVP32EH00R2L)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the flagship high-end main processing unit within the Delta DVP-EH3 Series, engineered for complex control and high-speed automation tasks. This base unit features 32 integrated digital I\/O points (16 inputs and 16 outputs) and utilizes a relay-based output architecture for robust switching across diverse industrial loads. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP32EH00R2-L\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis powered by a high-efficiency AC power supply and is distinguished by its superior execution speed and large program capacity. Designed for precision machinery, centralized control systems, and high-speed packaging lines, this EH3 series controller offers advanced motion control instructions and excellent expansion capabilities, ensuring maximum system flexibility and reduced cycle times in demanding 24\/7 manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe EH3 Series represents the pinnacle of Delta's DVP hardware evolution, featuring a hardware architecture optimized for high-speed logic and data processing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowered by a dual-processor engine, the EH3 delivers a basic instruction execution speed of 0.19 microseconds, significantly outperforming standard micro-PLCs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge Memory Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 30k steps of program memory and 12k words of data register, accommodating complex algorithms and extensive data logging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Output Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"R\" designation signifies relay outputs, providing dry contact switching suitable for both AC and DC voltages with high current-carrying capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Motion Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes four sets of hardware high-speed counters (up to 200 kHz) and supports linear\/arc interpolation instructions for multi-axis motion synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures built-in RS-232 and RS-485 ports with Modbus ASCII\/RTU protocol support, facilitating seamless integration with HMIs, drives, and SCADA systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDVP32EH00R2-L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDELTA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDVP-EH3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal I\/O Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 (16DI \/ 16DO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgram Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30k steps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Speed Counters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 sets (200 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Screw Mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.65 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the EH3 series and the standard EH2 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EH3 series provides significantly higher execution speeds (0.19 us vs 0.24 us), larger program memory, and improved high-speed counter performance. Additionally, the EH3 supports more advanced motion control instructions and features better EMI\/EMC shielding for noisy industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I expand the I\/O capacity of the DVP32EH00R2-L?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This main unit supports the full range of DVP-EH series expansion modules. You can add digital I\/O, analog I\/O, temperature measurement modules, and specialized communication cards to a maximum of 512 I\/O points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the internal RTC (Real Time Clock) included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP32EH00R2-L\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes a built-in Real Time Clock as standard. This is critical for applications requiring time-stamping, scheduled operations, or historical data logging.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile relay outputs are robust, switching inductive loads (such as solenoids or contactors) can cause contact arcing. For DC loads, install a flyback diode across the load; for AC loads, use an RC snubber circuit to extend the mechanical life of the PLC's internal relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting the PLC in a control cabinet, ensure at least 50 mm of clearance above and below the unit for natural convection. Avoid installing the unit directly above heat-producing devices like high-power servo drives or transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo minimize electromagnetic interference (EMI) and ensure stable high-speed counter readings, connect the \"S\/S\" and \"FG\" terminals to a low-impedance system ground. Use shielded twisted-pair cables for all high-speed signal inputs and RS-485 communication lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102417707371,"sku":"DVP32EH00R2-L","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/DVP32EH00R2-L-1lp5mzi0jw1.png?v=1776137321","url":"https:\/\/www.plcprotech.com\/products\/delta-dvp32eh00r2-l-eh3-series-high-performance-plc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}