{"product_id":"delta-dvp60es00r2-es-series-standard-plc-main-processing-unit","title":"Delta DVP60ES00R2 ES Series Standard PLC Main Processing Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP60ES00R2 (DVP 60ES00R2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Main Processing Unit (MPU) within Delta's renowned DVP-ES series, designed to provide robust and cost-effective automation for industrial control systems. Featuring 60 integrated I\/O points, this base unit is a premier choice for applications requiring extensive digital connectivity, such as centralized HVAC monitoring, large-scale conveyor systems, and automated warehouse management. Unlike its transistor-output counterparts, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP60ES00R2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes mechanical relay outputs, offering superior flexibility for switching various AC and DC load voltages. This unit provides a stable, reliable platform for logic execution, effectively serving as the \"brain\" of complex machinery while minimizing the need for multiple expansion modules.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe DVP60ES00R2 is built for versatility in power-heavy environments. It features 36 digital inputs and 24 relay-type digital outputs. The relay architecture allows for higher current carrying capacity and the ability to switch different voltage potentials across channels, which is ideal for driving heavy-duty contactors or solenoid valves directly. Powered by an integrated AC power supply (100 to 240 VAC), it eliminates the requirement for separate 24 VDC power converters for the CPU logic. The module supports dual communication ports (RS-232 and RS-485), enabling simultaneous connection to a PC for programming and an HMI or VFD for real-time control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDVP60ES00R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDVP-ES Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMPU Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMain Processing Unit (Base Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal I\/O Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 (36 Inputs \/ 24 Outputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay (Mechanical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 240 VAC (-15 percent \/ +10 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 and RS-485 (Master\/Slave)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgram Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4k Steps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel (5 A per common)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExecution Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 micro-s (Basic instruction)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1.0 kg (2 kg shipping weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"R\" (Relay) output in the DVP60ES00R2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe relay outputs provide dry contacts that can switch both AC and DC voltages (up to 250 VAC or 30 VDC). This makes the DVP60ES00R2 much more adaptable for systems where different output channels must control devices with varying power requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this model differ from the DVP60ES00T2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both have 60 I\/O points, the \"R2\" suffix indicates Relay outputs, whereas \"T2\" indicates Transistor outputs. Relay models are better for high-load current switching, while transistor models are required for high-speed pulse outputs used in motion control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor the status of the I\/O without a computer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The front panel of the DVP60ES00R2 features a comprehensive array of LED indicators that provide real-time status for the Power, Run, and Error states, as well as individual status lights for every input and output point.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Contact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen switching inductive loads (like motor starters or brake coils), mechanical relay contacts can suffer from \"arcing.\" It is strongly advised to install an RC snubber for AC loads or a freewheeling diode for DC loads to extend the mechanical lifespan of the internal relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent electromagnetic interference (EMI) from affecting the PLC logic, ensure that high-voltage output wiring is physically separated from the low-voltage communication and input signal cables. Use dedicated cable ducting where possible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting \u0026amp; Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the unit on a standard 35 mm DIN rail in a vertical orientation. Ensure there is at least 50 mm of free space above and below the unit for natural air circulation. In high-vibration environments, use end-brackets to prevent the PLC from sliding along the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102413316459,"sku":"DVP60ES00R2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/DVP60ES00R2-kxmehi4xljt.png?v=1776137333","url":"https:\/\/www.plcprotech.com\/products\/delta-dvp60es00r2-es-series-standard-plc-main-processing-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}