{"product_id":"delta-dvp60es200re-dvp-es2-series-standard-plc-with-ethernet","title":"DELTA DVP60ES200RE | DVP-ES2 Series Standard PLC with Ethernet","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP60ES200RE (DVP60ES200RE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the pinnacle of Delta's DVP-ES2 Series, engineered for high-performance sequential control in demanding industrial environments. This modular PLC integrates 36 digital inputs and 24 digital outputs (totaling 60 I\/O points), providing a robust control backbone for large-scale automation projects. Specifically designed for high-speed data exchange via its built-in Ethernet communication port, it is a critical component in smart manufacturing, water treatment facilities, and automated packaging lines. By facilitating seamless integration into Industrial Internet of Things (IIoT) architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP60ES200RE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes system latency and ensures maximum uptime for mission-critical operations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVP60ES200RE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built on the advanced ES2 logic platform, optimized for both discrete and process control. The \"E\" suffix designates its enhanced Ethernet capabilities, supporting Modbus TCP and EtherNet\/IP protocols for real-time monitoring and remote diagnostics.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessing Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed execution of basic instructions at 0.35 microseconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a high-density 60-point configuration, reducing the need for multiple expansion modules and saving valuable DIN-rail space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated RJ-45 Ethernet port alongside RS-232 and RS-485 ports, allowing simultaneous connection to HMI, SCADA, and downstream frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes robust relay outputs capable of handling diverse load types, offering superior isolation and higher current capacity compared to transistor outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDVP60ES200RE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDELTA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDVP-ES2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 Digital Inputs (DC Sink\/Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Relay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 microseconds (Basic Instruction)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet, RS-232, RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChina \/ Taiwan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many expansion modules can be connected to the DVP60ES200RE?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DVP-ES2 series supports up to 8 special expansion modules (including Analog I\/O, temperature measurement, and motion control) and a maximum of 256 total I\/O points, ensuring scalability for future system upgrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the Relay output in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe relay output provides dry contact switching, which allows the PLC to control different voltage levels (both AC and DC) and offers higher resistance to electrical noise and voltage surges compared to solid-state outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this PLC support remote programming via Ethernet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the built-in Ethernet port allows for remote program upload\/download, online monitoring, and firmware updates through Delta's WPLSoft or ISPSoft software suites across a local network or VPN.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be checked if the 'ERROR' LED is flashing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA flashing ERROR LED typically indicates a program syntax error, an I\/O configuration mismatch, or a hardware watchdog timer timeout. Check the error code via the peripheral communication port using Delta's diagnostic software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Shielding and Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor stable communication in high-EMI environments (near VFDs or large motors), utilize shielded Cat5e or Cat6 cables. Ensure the shield is grounded at the switch end to prevent ground loops that can corrupt data packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure a long service life, maintain a minimum clearance of 50 mm above and below the unit for natural convection. If the ambient temperature inside the enclosure exceeds 50 deg C, forced air cooling is mandatory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen switching inductive loads (such as solenoid valves or contactors), always install a snubber circuit (RC for AC loads, flyback diode for DC loads) across the load to prevent back-EMF from prematurely wearing out the internal relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102413447531,"sku":"DVP60ES200RE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/dvp60es200re-ijlkvm2d3y1.png?v=1776137337","url":"https:\/\/www.plcprotech.com\/products\/delta-dvp60es200re-dvp-es2-series-standard-plc-with-ethernet","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}