{"product_id":"delta-vfd150c43a-delta-products-ac-drives-c2000-series","title":"Delta VFD150C43A Delta Products AC Drives, C2000 Series","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDelta VFD150C43A\u003c\/strong\u003e is a high-performance variable frequency drive belonging to the \u003cstrong\u003eC2000 Series\u003c\/strong\u003e, designed for demanding industrial motor control applications. This \u003cstrong\u003eAC Drive\u003c\/strong\u003e is engineered to provide precise speed and torque control for 15kW (20HP) motors operating on a 460V 3-phase power supply. Utilizing advanced field-oriented vector control, this drive ensures stability in complex motion control tasks, pump and fan applications, and heavy-duty industrial machinery. The unit delivers a rated output capacity of 25 kVA and a rated output current of 32 A, providing the necessary robust performance for integrated automation systems requiring reliable speed regulation and energy efficiency.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance field-oriented control (FOC)\u003c\/li\u003e\n\u003cli\u003eWide power range compatibility for industrial motors\u003c\/li\u003e\n\u003cli\u003ePrecise speed and torque regulation\u003c\/li\u003e\n\u003cli\u003eIntegrated protective functions for motor and drive safety\u003c\/li\u003e\n\u003cli\u003eDesigned for 3-phase 460V power distribution systems\u003c\/li\u003e\n\u003cli\u003eCompact footprint for efficient panel space utilization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC systems (fans and pumps)\u003c\/li\u003e\n\u003cli\u003eConveyor systems\u003c\/li\u003e\n\u003cli\u003eExtrusion machinery\u003c\/li\u003e\n\u003cli\u003eTextile equipment\u003c\/li\u003e\n\u003cli\u003eMetal processing machinery\u003c\/li\u003e\n\u003cli\u003eCrane and hoist applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDelta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eC2000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVFD150C43A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e460V 3-PHASE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Motor Capacity\u003c\/td\u003e\n\u003ctd\u003e15kW (20HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Capacity\u003c\/td\u003e\n\u003ctd\u003e25 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Ensure the drive is mounted vertically on a flat, non-flammable surface to allow for proper heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation\u003c\/strong\u003e: Maintain adequate clearance around the unit to facilitate airflow; avoid installing in areas with excessive dust, humidity, or corrosive gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Proper equipment grounding is essential to reduce electrical noise and ensure safety; use a dedicated ground terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Use shielded cables for control signals to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Ensure input and output power cables are sized correctly according to the rated current (32 A) and local electrical codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Operate within the specified temperature ranges; if the ambient temperature exceeds the rated limit, forced cooling must be provided.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102154613099,"sku":"VFD150C43A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd150c43a-kezux0cxrl2.png?v=1776138071","url":"https:\/\/www.plcprotech.com\/products\/delta-vfd150c43a-delta-products-ac-drives-c2000-series","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}