{"product_id":"e82zafcc100-lenze-8200-vector-can-i-o-rs-pt-module","title":"E82ZAFCC100 Lenze 8200 Vector CAN-I\/O RS PT Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFCC100 (E82ZAFCC100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision CAN-I\/O communication and functional interface designed for the Lenze 8200 Vector inverter range. In high-demand B2B sectors such as food processing, automated warehousing, and pharmaceutical packaging, this module acts as a localized controller and networking hub. By utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFCC100\u003c\/strong\u003e, engineers can achieve rapid data exchange across System Bus (CAN) networks, significantly improving the synchronization of multi-axis drive systems. This reduces mechanical stress on motor couplings and minimizes the risk of production line bottlenecks. Despite its \"Phase-Out\" status, this module remains an essential component for maintaining and optimizing legacy 8200 Vector architectures where high-speed signal processing is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFCC100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is built around the CANopen protocol, providing a robust RS-485 physical layer interface for deterministic communication. This \"PT\" (Pluggable Terminal) variant is engineered for modularity, allowing for rapid hardware swaps without the need for complex rewiring. It features an integrated internal logic processor that handles basic I\/O tasks independently of the main inverter CPU, reducing the computational load on the drive. The unit supports various baud rates and PDO (Process Data Object) mapping, making it highly adaptable to diverse industrial bus structures. Its compact 5.10 cm width ensures it fits seamlessly into the inverter's standard expansion slot without increasing the drive's footprint.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE82ZAFCC100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN-I\/O (System Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCANopen \/ RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8200 Vector Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.10 x 7.60 x 2.50 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85044095\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECCN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the E82ZAFCC100 require external power for the CAN communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module is powered internally through the 8200 Vector inverter's interface slot. However, ensure the inverter control terminals are correctly powered to maintain signal logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length supported by the CAN interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe distance depends on the baud rate. At 1 Mbit\/s, the maximum cable length is 40 meters. For longer runs (up to 1000 meters), the baud rate must be reduced to 20 kbit\/s or lower.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used for basic digital I\/O expansion without a CAN network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module includes integrated I\/O terminals that can be utilized as local digital inputs or outputs, even if the CANopen networking capabilities are not fully exploited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the inverter does not recognize the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, ensure the module is fully seated in the slot and the locking screws are secure. Check parameter C0002 to verify if the inverter requires a manual reset to initialize the new hardware.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Termination and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CAN bus must be terminated with a 120 Ohm resistor at both ends of the physical line to prevent signal echoes. When wiring the RS-485\/CAN terminals, use twisted-pair shielded cables. The shield should be grounded at the inverter's PE (Protective Earth) rail using a low-impedance clamp to prevent electromagnetic interference from the motor cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Plugging Prohibition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNever install or remove the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFCC100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile the inverter is powered on. Doing so can cause electrical arcing across the interface pins, potentially damaging the control board of the 8200 Vector drive. Always wait at least 3 to 5 minutes after power-down for the DC bus capacitors to discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile rated for up to 55 deg C, in environments with high humidity or chemical vapors, ensure the control cabinet is equipped with an appropriate air filter or heat exchanger. The module's PCB is sensitive to conductive dust, which can lead to short circuits between the high-density pin headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105061658987,"sku":"E82ZAFCC100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafcc100-1ya0no4nb2z.png?v=1776235965","url":"https:\/\/www.plcprotech.com\/products\/e82zafcc100-lenze-8200-vector-can-i-o-rs-pt-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}