{"product_id":"emerson-a6110-shaft-relative-vibration-monitor","title":"Emerson A6110 AMS 6500 Shaft Relative Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson A6110\u003c\/strong\u003e is a shaft relative vibration monitor designed for monitoring rotating machinery critical assets within the AMS 6500 Machinery Health Monitor architecture. The \u003cstrong\u003eA6110\u003c\/strong\u003e standard 1-slot hot-swappable module accepts input signals from non-contact displacement sensors via two independent or combined monitoring channels. Built to API 670 machinery protection standards, the module interfaces with the system backplane and Modbus TCP\/IP communication networks to deliver dynamic signal processing, including Smax, 1x, 2x, 1\/2x, and phase angle tracking. The card integrates directly into PlantWeb and DeltaV network platforms to deliver real-time machine malfunction detection and protection for industrial turbo machinery.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAPI 670 compliant 1-slot hot-swappable protection module architecture\u003c\/li\u003e\n\u003cli\u003eIndependent dual-channel or combined monitoring modes (Smax, True S peak-to-peak)\u003c\/li\u003e\n\u003cli\u003eFront and rear raw buffered outputs with 0.1-16 kHz frequency range\u003c\/li\u003e\n\u003cli\u003eDedicated 0-10 VDC shaft position (gap) voltage outputs per channel\u003c\/li\u003e\n\u003cli\u003eIntegrated Mini DIN front panel connector supporting RS-232 configuration interfaces\u003c\/li\u003e\n\u003cli\u003eSelf-checking diagnostics monitoring hardware integrity, sensor connections, cable conditions, and internal temperature\u003c\/li\u003e\n\u003cli\u003eRemote-selectable limit multiply and trip bypass capabilities\u003c\/li\u003e\n\u003cli\u003eProportional 0\/4-20 mA and 0-10 VDC output options per channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbines\u003c\/li\u003e\n\u003cli\u003eGas turbines\u003c\/li\u003e\n\u003cli\u003eHydro turbo machinery\u003c\/li\u003e\n\u003cli\u003eIndustrial turbo compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eProduct Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA6110\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA6110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo, independent or combined monitoring modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to -22 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLower cutoff 1 or 5 Hz; Upper cutoff 50-2000 Hz adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSmallest Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-400 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLargest Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-8000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Power Nominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-26.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Power Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 20 mA, maximum 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Buffered Output Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 100 Ohm load, freq. range 0.1-5 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\/4-20 mA proportional to main value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Output Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC proportional to main value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Output Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Gap Voltage Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC proportional to shaft position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Buffered Output Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1-16 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSettling Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable 0-10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlert and Danger, selectable normally open or normally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Time Delays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-5 second delay per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Space\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMini DIN Front Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 interface for module configuration, parameters, and status monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Buffered Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual raw signal outputs identical to transducer sensor inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Current Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 0\/4-20 mA outputs proportional to channel main value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Voltage Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 0-10 VDC outputs proportional to main value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear DC Voltage Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 0-10 VDC outputs proportional to shaft position (gap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Buffered Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual AC\/DC raw buffered output signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated relay input terminals for Limit Multiply and Trip Bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Insert the 1-slot hot-swappable module into the designated slot of the AMS 6500 rack housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandle Assembly:\u003c\/strong\u003e Utilize the integrated front handle to insert or remove the card from the rack frame and display point identification label tags.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Isolation:\u003c\/strong\u003e Ensure field transducer input cables are galvanically separated from system voltages and power supply lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfig Port Access:\u003c\/strong\u003e Connect an RS-232 communication cable to the front-panel Mini DIN interface socket for local parameter adjustment via configuration software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachinery Protection:\u003c\/strong\u003e API 670 compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695190208875,"sku":"A6110","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-a6110-shaft-relative-vibration-monitor-eqrtb51jeaz_2d8cdbba-9cc5-4790-8218-4cdf06977fce.jpg?v=1766114602","url":"https:\/\/www.plcprotech.com\/products\/emerson-a6110-shaft-relative-vibration-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}