{"product_id":"emerson-kj3002x1-bc1-deltav-2-wire-ai-8-channel-4-20-ma-card","title":"Emerson KJ3002X1-BC1 DeltaV 2-Wire AI 8-Channel 4-20 mA Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEmerson KJ3002X1-BC1\u003c\/strong\u003e is a 2-wire analog input card featuring 8 channels designed for 4-20 mA signals. The \u003cstrong\u003eKJ3002X1-BC1\u003c\/strong\u003e converts 4-20 mA continuous current signals collected from field transmitters and sensors into digital data for processing within the DeltaV distributed control system. It operates within the DeltaV M-series traditional I\/O structure, connecting field instrumentation via a terminal block key position A1 interface.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures an 8-channel design configured for 2-wire 4-20 mA analog input signals.\u003c\/li\u003e\n\u003cli\u003eIntegrates a rotary keying system to ensure correct mechanical alignment with terminal blocks.\u003c\/li\u003e\n\u003cli\u003eSupports removal and insertion while system power is energized under specified loop conditions.\u003c\/li\u003e\n\u003cli\u003eEliminates field maintenance requirements with a design that requires no calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed control system (DCS) field instrumentation processing.\u003c\/li\u003e\n\u003cli\u003eIndustrial continuous process monitoring using 4-20 mA current loops.\u003c\/li\u003e\n\u003cli\u003eHazardous atmosphere process automation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3002X1-BC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power Rating\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBussed Field Power Rating\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10g 1\/2 Sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1mm Peak to Peak from 5 to 16Hz; 0.5g from 16 to 150Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Airborne Contaminants Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Key Position\u003c\/td\u003e\n\u003ctd\u003eA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Removal:\u003c\/strong\u003e Field power supplied to the device, at either the field terminal or as bussed field power through the carrier, must be removed before removing or connecting the card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive Insertion Conditions:\u003c\/strong\u003e The unit may be removed or inserted while system power is energized provided that only one unit is removed at a time and it is used with a KJ1501X1-BC1 System Dual DC\/DC Power Supply operating on 24 VDC or 12 VDC input power. Primary circuit wiring inductance for input power must be less than 23 uH, or supplied via a certified supply with an open circuit voltage Ui of 12.6 VDC and Lo of less than 23 uH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying System:\u003c\/strong\u003e Verify that the rotary keying system on the terminal block is set to position A1 for compatibility prior to card insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Fuse:\u003c\/strong\u003e Do not remove a terminal block fuse with field power energized for non-sparking circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e The unit contains no user-serviceable parts and must not be disassembled.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX: II 3 G, EEx nL IIC T4 (Nemko No. 02ATEX431U)\u003c\/li\u003e\n\u003cli\u003eCSA \/ Safety Approvals: LR87534 APPROVED, Class I Division 2 Groups A, B, C, D, Temp Rating T4\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695192109419,"sku":"KJ3002X1-BC1 ","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-kj3002x1-bc1-12p0681x092-ve4003s1b2-deltav-analog-input-card-2f3sgcorq34_067eaa56-a866-4721-b844-dcfb21cc5d9c.jpg?v=1766114673","url":"https:\/\/www.plcprotech.com\/products\/emerson-kj3002x1-bc1-deltav-2-wire-ai-8-channel-4-20-ma-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}