{"product_id":"emerson-pr9268-017-100-electrodynamic-velocity-sensor","title":"Emerson PR9268\/017-100 Electrodynamic Velocity Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson PR9268\/017-100\u003c\/strong\u003e is a mechanical electrodynamic velocity sensor designed for absolute vibration measurement of critical turbomachinery applications. It provides case vibration monitoring for systems such as steam, gas, and hydro turbines, as well as compressors, pumps, and fans. Operating as a self-powered device, this \u003cstrong\u003evelocity sensor\u003c\/strong\u003e converts mechanical vibration into an electrical signal proportional to velocity, transmitting dynamic data to continuous machinery protection systems like AMS monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical velocity sensor design optimized for critical turbomachinery protection.\u003c\/li\u003e\n\u003cli\u003eSelf-powered design requiring no external excitation power for signal generation.\u003c\/li\u003e\n\u003cli\u003eRobust housing constructed from stainless steel for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eOmni-directional sensor orientation capability enabling versatile mounting configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas, and hydro turbine case vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eTurbo-compressor vibration measurement.\u003c\/li\u003e\n\u003cli\u003eHigh-performance industrial pumps and ventilation fans.\u003c\/li\u003e\n\u003cli\u003ePower plant and petrochemical industrial rotating machinery protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOmni Directional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mV\/mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 to 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNatural Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 Hz $\\pm$ 7% @ 20 degC (68 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 @ 80 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Amplitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 $\\mu$m peak-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Acceleration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10g (98.1 $m\/s^2$) peak-peak continuous \/ 20g (196.2 $m\/s^2$) peak-peak intermittent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transverse Acceleration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2g (19.62 $m\/s^2$)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDamping Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~0.696 @ 20 degC (68 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1723 $\\Omega$ $\\pm$ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e$\\le$ 90 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActive Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.2 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +100 degC (-4 to 212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 100%, Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Core Material \/ Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTFE, 3x 0.5 $mm^2$\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDie Cast Aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the sensor is securely attached to the machine housing using the specified M10x1 threads.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing to prevent mechanical stress or wear on the armored cable assembly.\u003c\/li\u003e\n\u003cli\u003eKeep the integrated shielding grounded according to standard industrial machinery protection procedures to eliminate EMI\/RFI noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE\u003c\/strong\u003e: 2014\/30\/EU (EN 61326-1), 2014\/34\/EU, 2011\/65\/EU (EN 63000)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA\u003c\/strong\u003e: S.I. 2016 No. 1091, S.I. 2016 No. 1107, S.I. 2012 No. 3032\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695187259755,"sku":"PR9268\/017-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr9268-017-100-epro-mechanical-velocity-sensor-gpdx5p2ptbq_d1361f41-0858-4cd6-b7e9-144c18f4f774.jpg?v=1766114502","url":"https:\/\/www.plcprotech.com\/products\/emerson-pr9268-017-100-electrodynamic-velocity-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}