{"product_id":"emerson-ss6501t01-deltav-sis-redundant-csls-assembly-copper","title":"Emerson SS6501T01 DeltaV SIS Redundant CSLS Assembly - Copper","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson SS6501T01 DeltaV SIS Redundant CSLS Assembly - Copper\u003c\/strong\u003e is a Safety Integrity Level 3 (SIL 3) capable logic solver module designed for process safety applications within the DeltaV SIS system. It integrates I\/O processing, safety logic execution, and diagnostics into a single redundant logic solver assembly using Emerson Electronic Marshalling technology. The \u003cstrong\u003eSS6501T01\u003c\/strong\u003e connects directly to standard copper Ethernet infrastructure for redundant Safety Network Port (SNP) communications on the Local Safety Network (LSN).\u003c\/p\u003e\n\u003cp\u003eThe module supports execution of safety instrumented functions (SIF) with deterministic execution rates independent of system size. Operating in lock-step mode, the redundant CSLS pair provides bumpless switchover upon fault detection without process disturbance. Integrated HART I\/O capabilities pass field diagnostics directly to the logic solver and support partial stroke testing for digital valve controllers. The unit mounts via DIN rail latching and interfaces with up to 8 CHARM baseplates (supporting up to 96 individually configurable LS CHARM channels).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSIL 3 rated for both simplex and redundant operating architectures.\u003c\/li\u003e\n\u003cli\u003eRedundant logic solver pair operating in lock-step execution.\u003c\/li\u003e\n\u003cli\u003eIntegrated support for up to 96 local LS CHARM I\/O channels per assembly.\u003c\/li\u003e\n\u003cli\u003eRedundant Safety Network Ports (SNP) for copper twisted-pair Ethernet LSN connections.\u003c\/li\u003e\n\u003cli\u003eIntegrated HART protocol support for embedded field diagnostics and partial stroke testing.\u003c\/li\u003e\n\u003cli\u003eAutomatic online sensing and auto-configuration within the DeltaV SIS database.\u003c\/li\u003e\n\u003cli\u003eContinuous diagnostic self-testing with automatic alarm generation.\u003c\/li\u003e\n\u003cli\u003eSequence of Events (SOE) time stamping with resolution of less than 1 ms.\u003c\/li\u003e\n\u003cli\u003eClass 1, Div 2 \/ Zone 2 hazardous location rating with G3 conformal coating.\u003c\/li\u003e\n\u003cli\u003eSnap-together DIN rail latching mechanism.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Systems (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eHigh Integrity Pressure Protection Systems (HIPPS)\u003c\/li\u003e\n\u003cli\u003eCritical process safety instrumented functions up to SIL 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRedundant CSLS Assembly - Copper (Includes CSLS Carrier, \u003c\/p\u003e\n\u003cp\u003e2 CSLSs, 2 Power Modules, \u003c\/p\u003e\n\u003cp\u003e2 single Safety Network Ports for twisted copper, 2 Power Plugs)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSS6501T01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSS6501T01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant CSLS Assembly - Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power (Redundant)\u003c\/td\u003e\n\u003ctd\u003e+24 V DC +\/-10% at 12.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSLS Power Requirement\u003c\/td\u003e\n\u003ctd\u003e+24 V DC +\/-10% at 325 mA max (simplex); 575 mA max (redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Module Output to LS CHARMs\u003c\/td\u003e\n\u003ctd\u003e+6.3 V DC +\/-3% at 4 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e18 W maximum per carrier with redundant CSLS pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of I\/O Channels\u003c\/td\u003e\n\u003ctd\u003e96 channels (up to 48 output channels max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum CSLSs per System\u003c\/td\u003e\n\u003ctd\u003e1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum CSLSs per SZ Controller\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Update Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRedundant 10\/100BASE-TX RJ45 copper twisted-pair (SNP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLSN Distance Limit\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC (-40 to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3 Conformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1 mm Peak-to-Peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail latch to vertical oriented T-type rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the CSLS carrier vertically at the top of the T-type DIN rail using the integrated rail latches.\u003c\/li\u003e\n\u003cli\u003eInstall a DIN rail stop (VE4054DRS) to secure the assembly in position.\u003c\/li\u003e\n\u003cli\u003eConnect dual 24 V DC field power feeds to the redundant power connections on the carrier.\u003c\/li\u003e\n\u003cli\u003eAttach copper twisted-pair Ethernet cables (10\/100BASE-TX) to the primary and secondary Safety Network Ports (SNP) with a maximum cable distance of 100 meters.\u003c\/li\u003e\n\u003cli\u003eAttach up to eight CHARM baseplates below the carrier assembly and install bus termination at the end of the physical bus.\u003c\/li\u003e\n\u003cli\u003eEnsure cabinet installations meet IP20 requirements and maintain adequate spacing for cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e: SIL 3 Capable (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standard\u003c\/strong\u003e: EN 61326-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM (USA)\u003c\/strong\u003e: Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2: AEx ec IIC Gc T4 \/ AEx ec nC IIC T4 \/ AEx ec [ic] IIC Gc T4 \/ AEx ec ic IIC Gc T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecFM (Canada)\u003c\/strong\u003e: Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2: Ex ec IIC Gc T4 \/ Ex ec nC IIC Gc T4 \/ Ex ec [ic] IIC Gc T4 \/ Ex ec ic IIC Gc T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\u003c\/strong\u003e: II 3G Ex ec IIC T4 Gc \/ II 3G Ex ec [ic] IIC T4 Gc \/ II 3G Ex ec ic IIC T4 Gc \/ II 3G Ex ec nC IIC T4 Gc (EN60079-0, EN60079-7, EN60079-15)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx\u003c\/strong\u003e: II 3G Ex ec IIC T4 Gc \/ II 3G Ex ec [ic] IIC T4 Gc \/ II 3G Ex ec ic IIC T4 Gc \/ II 3G Ex ec nC IIC T4 Gc (IEC60079-0, IEC60079-7, IEC60079-15)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine\u003c\/strong\u003e: IACS 10, ABS Certificate of Design Assessment, DNV Marine Certificate\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53630769627499,"sku":"SS6501T01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Emerson-SS6501T01_14e008b8-cc8e-4ccc-bf27-10eacc522f83.jpg?v=1785414356","url":"https:\/\/www.plcprotech.com\/products\/emerson-ss6501t01-deltav-sis-redundant-csls-assembly-copper","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}