{"product_id":"emerson-ve5009-kj1501x1-bc3-12p3935x022-enhanced-system-power-supply","title":"Emerson VE5009 KJ1501X1-BC3 12P3935X022 Enhanced System Power Supply","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE5009\u003c\/strong\u003e is a modular, plug-and-play system power supply engineered to provide stable, reliable power to DeltaV controllers and I\/O interfaces. As an integral component of the DeltaV M-series infrastructure, this \u003cstrong\u003e24\/12-VDC Enhanced System Power Supply\u003c\/strong\u003e supports dual input voltage configurations, efficiently accommodating both 12 VDC and 24 VDC plant bulk power. When operating on 24 VDC bulk power, the \u003cstrong\u003eVE5009\u003c\/strong\u003e delivers up to 8 Amps of current directly down the LocalBus to the I\/O subsystem, eliminating the need for standalone 24-to-12 VDC intermediate bulk power converters. The device features flexible load-sharing capabilities to facilitate system scaling and power redundancy, comprehensive under\/over-voltage fault detection to safeguard downstream logic electronics, and absolute isolation between system power and field circuits.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlug-and-play modular design allows seamless insertion into any horizontal 2-wide or vertical 4-wide power\/controller carrier slot.\u003c\/li\u003e\n\u003cli\u003eUtilizes internal power buses within the carrier system, eliminating the requirement for external interconnecting cables between the power supply, controller, and I\/O interface carriers.\u003c\/li\u003e\n\u003cli\u003eDual input capability supports flexible integration into existing 12 VDC or 24 VDC power systems.\u003c\/li\u003e\n\u003cli\u003eSupports load-sharing architectures to economically implement 1-to-N or 1-to-1 system power redundancy.\u003c\/li\u003e\n\u003cli\u003eIntegrated fault detection monitors voltage limits to ensure automatic cold restart capabilities for the controller following bulk power anomalies.\u003c\/li\u003e\n\u003cli\u003eDedicated front panel LED indicators provide real-time diagnostic visibility for normal DC operation and error status.\u003c\/li\u003e\n\u003cli\u003eBuilt-in 2-wire normally open relay alarm contact changes state immediately upon internal output drift or bulk supply input collapse.\u003c\/li\u003e\n\u003cli\u003eRestricts system and field power routing to independent isolated paths when sourced from a common 24 VDC system.\u003c\/li\u003e\n\u003cli\u003eQuick-mount bulk power input connector simplifies routing and allows efficient module replacement compared to conventional fixed terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) system logic and interface power management\u003c\/li\u003e\n\u003cli\u003eCritical process control loop automation and redundant carrier power networks\u003c\/li\u003e\n\u003cli\u003eHeavy industrial process plants requiring hazardous location certified power modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Assembly Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\/12-VDC Enhanced System Power Supply\u003c\/td\u003e\n\u003ctd\u003eVE5009\u003c\/td\u003e\n\u003ctd\u003eKJ1501X1-BC3 (Assembly: 12P3935X022)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson Process Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturing Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAstec Intl. Ltd. - Phil. Branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage (12 VDC Mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC (-4% to +5%) at 14.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage (24 VDC Mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/- 20% at 6.1 A (or 5.4 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current (12 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A peak maximum for 5 ms over 12 VDC input range (excluding 12 VDC output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current (24 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A peak maximum for 5 ms over 24 VDC input range (including 12 VDC output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Ratings (-40 to 60 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+12 VDC at 13.0 A (12 VDC Input)\u003c\/p\u003e\n\u003cp\u003e+12 VDC at 8.0 A (24 VDC Input)\u003c\/p\u003e\n\u003cp\u003e+5.1 VDC at 2.0 A (also listed as +5 VDC)\u003c\/p\u003e\n\u003cp\u003e+3.4 VDC at 2.0 A (also listed as +3.3 VDC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombined System Logic Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2 Watts Maximum total from combined +5.1 VDC and +3.4 VDC outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Ratings (60 to 70 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+12 VDC at 10.0 A (12 VDC Input)\u003c\/p\u003e\n\u003cp\u003e+12 VDC at 6.0 A (24 VDC Input)\u003c\/p\u003e\n\u003cp\u003e+5.1 VDC at 2.0 A\u003c\/p\u003e\n\u003cp\u003e+3.4 VDC at 2.0 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternally fused, non-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput protected at 110% to 120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold-up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput remains within 5% of nominal at full load and minimum input voltage for 5 ms (excluding 12 VDC current with 12 VDC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to 60 degC (-40 to 140°F) without de-rating\u003c\/p\u003e\n\u003cp\u003e60 to 70 degC (140 to 158°F) with de-rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC (-40 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirborne Contaminants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 airborne contaminants class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 g 1\/2-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak from 5 Hz to 16 Hz, 0.5 g from 16 Hz to 150 Hz (or 1 mm peak-to-peak from 2 to 13.2 Hz, 0.7 g from 13.2 to 150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus LED Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGreen: DC Power (Input applied, internal fuse\/diode intact)\u003c\/p\u003e\n\u003cp\u003eRed: Error (+5.1 VDC and +3.4 VDC outputs are out of tolerance)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Pin \/ Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Pin 1 \u0026amp; 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC Primary Bulk Input (+ \/ -)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Pin 3 \u0026amp; 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC Primary Bulk Input (+ \/ -)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Relay Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-wire normally open dry contact relay; closes when internal system logic rails (3.4 VDC and 5.1 VDC) are within 4% of nominal. Rating: 30V VDC at 2.0 A or 250 VAC at 2.0 A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Attachment:\u003c\/strong\u003e The module must only be mounted onto a pre-installed, T-type DIN rail-supported DeltaV Power\/Controller carrier (including 2-wide horizontal, 4-wide vertical, or Vertical Plus variants).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Constraints (Live-Work):\u003c\/strong\u003e This unit cannot be removed or inserted while the system power is energized. Ensure the bulk source is fully isolated before handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 VDC Passthrough Conditions:\u003c\/strong\u003e The external voltage source feeding this module in 12 VDC passthrough mode must not generate or contain a potential exceeding 12.6 VDC in normal operation and must supply no more than 16 A maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation and De-rating:\u003c\/strong\u003e Ensure clear spacing around the carrier array to allow unhindered air convection, especially when operating ambient boundaries approach the 60 to 70 degC de-rating window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Wiring:\u003c\/strong\u003e Refer to official instruction documents 12P2046 (Zone 2) or 12P1293 (Class 1 Division 2) for boundary containment requirements and grounding guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFM Approved: Class 1 Division 2, Groups A, B, C, D; Hazardous Locations; Temperature Rating T4\u003c\/li\u003e\n\u003cli\u003eATEX Certified: II 3G Ex nA nC IIC Gc; Certificate No: Nemko 07ATEX3058U\u003c\/li\u003e\n\u003cli\u003eCSA Certified: LR109492\u003c\/li\u003e\n\u003cli\u003eCE Approved\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695183032683,"sku":"KJ1501X1-BC3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-ve5009-kj1501x1-bc3-12p3935x022-power-supply-f0vs03r23go_90a7a8de-24e9-4e3f-80fe-fcad59bc7207.jpg?v=1766114363","url":"https:\/\/www.plcprotech.com\/products\/emerson-ve5009-kj1501x1-bc3-12p3935x022-enhanced-system-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}