{"product_id":"emp-2-danfoss-084g2113-industrial-pressure-transmitter","title":"EMP 2 Danfoss 084G2113 Industrial Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e084G2113 (084G2113)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty EMP 2 series pressure transmitter specifically engineered by Danfoss for marine and industrial applications where reliability under extreme conditions is paramount. Delivering a precision 4 - 20 mA output signal across a 0 - 40 bar pressure range, this unit is built to withstand high-vibration environments such as engine rooms, hydraulic power units, and water processing plants. With a typical accuracy of 0.5% FS and a rapid response time of 4 ms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e084G2113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the high-fidelity data required for real-time control loops and safety monitoring. Its robust \"Sealed Gauge\" reference ensures consistent performance by eliminating the influence of atmospheric pressure fluctuations, making it a critical asset for high-pressure system stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe EMP 2 platform (Specification Key: EMP 2-2631-F6CD24-2) is designed for maximum field durability. It features a unique electrical interface consisting of a terminal block housed within a Pg 13.5 cable entry, providing a more secure and vibration-resistant connection than standard plug-in types. The pressure interface is highly versatile, utilizing a G 1\/2 male connection with an internal G 1\/4 female thread, compliant with EN 228-1 standards. Internally, the transmitter is laser-calibrated for a compensated temperature range of 0 to 70 deg C, minimizing thermal drift. Safety and reliability are further enhanced by a high overload pressure rating of 80 bar and clipping levels (3.6 mA to 22.4 mA) that allow for advanced diagnostic detection of sensor faults or short circuits.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e084G2113 (EMP 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 40 bar (0 - 580 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA Current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (Typical)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5% FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealed Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Overload Pressure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Block (Pg 13.5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the terminal block connection over a standard plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe terminal block in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e084G2113\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for a direct, hard-wired connection that is less prone to loosening in high-vibration marine environments compared to DIN plugs. The Pg 13.5 cable gland provides a superior mechanical grip and environmental seal for the signal cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the clipping levels (3.6 \/ 22.4 mA) assist in system diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese levels define the sensor's output boundaries. If the PLC detects a signal below 3.6 mA or above 22.4 mA, it can immediately identify a hardware fault (such as a broken wire or sensor failure) rather than interpreting the data as a valid pressure reading, preventing incorrect automated responses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a specific mounting orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the EMP 2 is designed to be orientation-independent, it is best practice to mount it with the pressure port facing downwards in gas applications to prevent condensate accumulation, or horizontally in liquid systems to avoid air entrapment at the sensing diaphragm.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting to the internal terminal block, use ferrules on all stranded wire ends. Observe the polarity: connect the positive supply to terminal \"P\" and the common\/signal return to terminal \"N.\" Ensure the Pg 13.5 gland is tightened firmly to maintain the IP65 rating and protect the internal electronics from salt mist or humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverpressure Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the unit features an 80 bar overload rating, systems prone to severe hydraulic water hammer should utilize a damping snubber. The dual-thread G 1\/2 male \/ G 1\/4 female connection allows for flexible mounting of such protection accessories directly to the transmitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the medium temperature does not exceed the 70 deg C limit. In high-temperature steam or oil applications, use a pigtail syphon or a capillary stand-off to ensure the temperature at the sensor interface remains within the compensated range of 0 to 70 deg C for maximum accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419738987,"sku":"084G2113","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/084g2113-xjgd1zpoyq1.png?v=1776136987","url":"https:\/\/www.plcprotech.com\/products\/emp-2-danfoss-084g2113-industrial-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}