{"product_id":"fc-051p5k5t4e20hxbxcxxxsxxx-danfoss-vlt-micro-drive-fc-51","title":"FC-051P5K5T4E20HXBXCXXXSXXX Danfoss VLT Micro Drive FC 51","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051P5K5T4E20HXBXCXXXSXXX (136N8934)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged and compact frequency converter from the Danfoss VLT Micro Drive FC 51 series, engineered for high-density industrial environments. This 5.5 kW (7.5 HP) motor controller is designed to optimize the performance of three-phase AC motors in applications such as conveyor systems, industrial fans, and centrifugal pumps. By providing precise speed and torque control, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051P5K5T4E20HXBXCXXXSXXX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly enhances process efficiency while reducing mechanical stress on drivetrains. Its coated PCB architecture ensures long-term reliability in harsh operating conditions, making it a critical component for reducing energy consumption and minimizing operational overhead in modern manufacturing and water treatment facilities.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe technical capabilities of this specific unit are defined by its comprehensive configuration string, which dictates its hardware and software interface:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP5K5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDenotes a power rating of 5.5 kW (7.5 HP) optimized for heavy-duty industrial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies three-phase input compatibility with a mains voltage range of 380 - 480 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChassis design rated at IP20, suitable for protected cabinet mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHX:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo RFI Filter configuration, ideal for setups where external filtering is already present or not required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Brake Chopper, allowing the drive to dissipate regenerative energy during rapid deceleration or braking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCoated Printed Circuit Boards (PCB) for enhanced protection against humidity, dust, and airborne contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX (LCP):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard unit supplied without a Local Control Panel; requires external interface or separate LCP module for manual parameter adjustment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-051P5K5T4E20HXBXCXXXSXXX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e136N8934\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kW \/ 7.5 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 480 VAC (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated (Class 3C3 compatible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model include a built-in display for parameter monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the \"X\" designation in the LCP position indicates that this unit does not come with a Local Control Panel. For setup and monitoring, you must use a remote mounting kit, an LCP 11\/12 module, or the MCT 10 setup software via the RS485 interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC 51 be mounted side-by-side to save cabinet space?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the VLT Micro Drive features a unique bookstyle design that allows for true side-by-side mounting without derating. This enables maximum utilization of panel space in high-density electrical enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the Coated PCB (\"C\" suffix) in this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conformal coating protects the internal electronics from corrosion and short circuits caused by moisture or conductive dust. This is essential for maintaining uptime in industries like textiles, woodworking, or chemical processing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling and Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite the side-by-side mounting capability, ensure a minimum clearance of 100 mm above and below the unit. This maintains the necessary vertical convection airflow required to keep the internal heat sinks within safe operating limits at the 5.5 kW power rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Braking Implementation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this model includes an integrated brake chopper (Suffix B), an external brake resistor must be connected to terminals R+ and R- to handle regenerative energy during high-inertia stops. Ensure the resistor value (Ohms) matches the minimum requirements specified in the Danfoss technical manual to prevent chopper damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and RFI Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs this is the \"HX\" version (No RFI Filter), it is vital to use shielded motor cables and ensure a 360 degree low-impedance ground connection at both the drive and the motor. If the installation is near sensitive electronic equipment, consider installing an external RFI filter to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102415544683,"sku":"FC-051P5K5T4E20HXBXCXXXSXXX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-051p5k5t4e20hxbxcxxxsxxx-hhtkyi2ltif.png?v=1776137394","url":"https:\/\/www.plcprotech.com\/products\/fc-051p5k5t4e20hxbxcxxxsxxx-danfoss-vlt-micro-drive-fc-51","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}