{"product_id":"fc-302p11kt5e20h2xgc-danfoss-vlt-automationdrive-11kw","title":"FC-302P11KT5E20H2XGC Danfoss VLT AutomationDrive 11kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P11KT5E20H2XGC (131H1940)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 11 kW (15 HP) frequency inverter from the Danfoss VLT® AutomationDrive FC 302 series. Engineered for maximum flexibility and durability, this drive is designed to control a wide range of motor technologies in demanding industrial environments. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P11KT5E20H2XGC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis particularly suited for high-torque applications in sectors such as material handling, food and beverage processing, and chemical manufacturing. With its integrated Graphical Local Control Panel (LCP) and coated PCBs, this unit ensures high reliability and ease of use, even in atmospheres containing corrosive gases or moisture, significantly reducing the total cost of ownership through energy efficiency and minimized downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FC 302 platform is characterized by its modular design and superior motor control precision. This specific configuration includes high-tier hardware options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Control Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a Graphical LCP (G), allowing for multi-language display, trend graphs, and intuitive parameter setup directly at the drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures Coated PCBs (C) as standard, providing essential resistance against dust, humidity, and chemical contaminants in harsh industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower \u0026amp; Voltage Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports a broad mains voltage range of 380-500 VAC (Three Phase), making it adaptable to various international power standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an integrated H2 RFI filter, ensuring the drive meets strict industrial electromagnetic compatibility requirements without the need for external components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt into a robust IP20 enclosure, designed for optimized thermal management within a controlled electrical cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-302P11KT5E20H2XGC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131H1940\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 kW \/ 15 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 500 VAC (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH2 Class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphical LCP Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated PCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.53 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this 11 kW model support regenerative braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific configuration (Suffix X for Brake) does not include an internal brake chopper. If your application involves high-inertia loads or frequent rapid stops, you would need an external braking module or a different version of the FC 302 that includes the \"B\" suffix hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Graphical LCP benefit the operator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Graphical LCP provides a user-friendly interface with support for multiple languages and a \"Quick Menu\" for easy commissioning. It allows users to monitor real-time data, view performance charts, and quickly diagnose faults with descriptive text rather than just error codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in environments with high humidity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"C\" suffix indicates that the Printed Circuit Boards (PCBs) are coated with a conformal layer. This protects the internal electronics against moisture and corrosive particles, ensuring long-term reliability in environments like water treatment plants or textile mills.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Clearance for Cooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the 11 kW power output without thermal derating, ensure a minimum clearance of 100 mm above and below the drive. This allows the internal cooling fans to maintain proper airflow across the heat sink.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGraphical LCP Utilization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring commissioning, use the \"SmartStart\" guide on the Graphical LCP to automatically configure the motor nameplate data. Performing an Automatic Motor Adaptation (AMA) is highly recommended to optimize the drive's control over the specific motor's stator resistance and reactance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Grounding Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo fully leverage the H2 RFI filter, use shielded motor cables. The shield should be connected to the metal decoupling plate of the drive with a 360 degree clamp. This is critical for preventing high-frequency noise from interfering with nearby PLC signals or sensitive instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102414692715,"sku":"131H1940","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131h1940-1qnk2eiq2qv.png?v=1776137013","url":"https:\/\/www.plcprotech.com\/products\/fc-302p11kt5e20h2xgc-danfoss-vlt-automationdrive-11kw","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}