{"product_id":"fc-302p75kt5p55h2xgcxxxsxxxxa4bxcxxxxd0-danfoss-vlt-automationdrive-75kw","title":"FC-302P75KT5P55H2XGCXXXSXXXXA4BXCXXXXD0 Danfoss VLT AutomationDrive 75kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P75KT5P55H2XGCXXXSXXXXA4BXCXXXXD0 (FC-302P75KT5P55H2XGCXXXSXXXXA4BXCXXXXD0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT® AutomationDrive FC 302 designed for complex industrial applications requiring precision speed and torque control. This 75 kW (100 hp) advanced version is engineered to manage all asynchronous and permanent magnet motors with exceptional reliability. Built with a modular architecture, this specific unit features an IP55\/Type 12 enclosure for protection against dust and water, and is equipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass 3C3 conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon all PCBs to ensure durability in corrosive or harsh environments. With integrated DeviceNet connectivity and a 24 VDC backup supply option, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the central control hub for heavy-duty operations in mining, marine, and chemical processing industries.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe extensive model code defines a highly customized hardware and software configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e302\u003c\/strong\u003e: VLT® AutomationDrive Advanced Version.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP75K\u003c\/strong\u003e: 75 kW Power Rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT5\u003c\/strong\u003e: 380 - 500 VAC Three-phase mains voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP55\u003c\/strong\u003e: IP55 \/ Type 12 Enclosure rating (Wash-down protected).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH2\u003c\/strong\u003e: Integrated RFI-Filter, Class A2 (optimized for 55-75 kW).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX (Brake)\u003c\/strong\u003e: No integrated brake chopper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG\u003c\/strong\u003e: Graphical Local Control Panel (LCP-102) for advanced diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC\u003c\/strong\u003e: Conformal Coating on all PCBs (IEC 721-3-3 Class 3C3) for chemical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA4\u003c\/strong\u003e: VLT® DeviceNet MCA 104 Fieldbus option integrated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eD0\u003c\/strong\u003e: VLT® 24 V DC Supply Option MCB 107 for control power backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-302P75KT5P55\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVLT® AutomationDrive FC 302\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 kW \/ 100 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 - 500 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP55 \/ Type 12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating Class 3C3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet (MCA 104)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphical LCP-102\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Backup\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Supply (MCB 107)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the MCB 107 24 VDC Supply Option (D0)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe D0 suffix indicates the inclusion of the MCB 107 module. This allows the drive’s control logic, fieldbus (DeviceNet), and LCP to remain active even if the 400V mains power is disconnected. This is critical for maintaining communication with the master PLC and performing diagnostics during power outages or maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 3C3 Conformal Coating protect the drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Class 3C3 coating provides superior resistance against aggressive gases (such as Hydrogen Sulphide, Chlorine, and Ammonia). While standard drives fail due to corrosion on solder joints, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P75K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically built for environments like wastewater treatment or chemical plants where these gases are present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive require a separate interface for commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This unit comes with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLCP-102 Graphical Display\u003c\/strong\u003e. It supports multiple languages and provides trending graphs and setup wizards, allowing for full commissioning and troubleshooting without the need for external software, although MCT 10 software can still be used via the USB port.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIP55 Enclosure Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the IP55 rating, ensure that all cable glands are correctly sized and tightened. The entry plates must be sealed according to Danfoss specifications to prevent moisture or dust from entering the power section, which is critical for the 75 kW power electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEven with an IP55 rating, the drive generates significant heat at full 75 kW load. Ensure sufficient clearance around the drive and verify that the ambient temperature does not exceed 45 deg C without derating. The internal fans must have an unobstructed path for air circulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeviceNet Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen integrating the MCA 104 (A4 option) into a DeviceNet network, ensure that termination resistors (121 ohms) are placed at both ends of the trunk line. Use high-quality thick or thin DeviceNet cable to ensure signal integrity across the 75 kW electromagnetic environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416298347,"sku":"FC-302P75KT5P55H2XGCXXXSXXXXA4BXCXXXXD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-302P75KT5P55H2XGCXXXSXXXXA4BXCXXXXD0-oucbqaxt44e.png?v=1776137404","url":"https:\/\/www.plcprotech.com\/products\/fc-302p75kt5p55h2xgcxxxsxxxxa4bxcxxxxd0-danfoss-vlt-automationdrive-75kw","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}