{"product_id":"fs-sicc-1011-l15-honeywell-safety-manager-rusio-sic-to-female-sub-d-cable","title":"FS-SICC-1011\/L15 Honeywell Safety Manager RUSIO SIC to Female Sub-D Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-SICC-1011\/L15 \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized System Interconnection Cable (SIC) designed for the Honeywell Safety Manager and Safety Manager SC platforms. In high-integrity industrial environments—including offshore gas platforms, emergency shutdown (ESD) systems, and fire and gas (F\u0026amp;G) logic—this cable provides a reliable link between Remote Universal Safe I\/O (RUSIO) modules and field termination assemblies. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-SICC-1011\/L15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a robust Female Sub-D connector, engineered to maintain low contact resistance and high signal fidelity under continuous operation. By utilizing factory-prefabricated interconnection solutions, engineers can eliminate the wiring errors associated with manual field terminations, significantly accelerating commissioning times and ensuring the functional safety integrity of the entire control loop.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Technical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-SICC-1011\/L15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific nomenclature that defines the physical and electrical characteristics of the interconnection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFS-SICC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the component as a Safety Manager System Interconnection Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1011:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the specific pin-out configuration and internal conductor gauge optimized for the Universal I\/O (RUSIO) interface, supporting both analog and digital signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eL15:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the cable length. In this configuration, the suffix denotes a length of 15 meters, allowing for flexible cabinet-to-cabinet or cabinet-to-field marshalling installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFemale Sub-D:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a high-density, secure mechanical interface with the corresponding Field Termination Assembly (FTA) or interconnection board, featuring industrial-grade strain relief.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFS-SICC-1011\/L15\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Safety Manager\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFemale Sub-D (System Side to Field Side)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRUSIO SIC Interconnection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-purity Stranded Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 VDC \/ 50 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFlame Retardancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL 94 V-0 Rated Connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Maintenance FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FS-SICC-1011\/L15 compatible with redundant RUSIO configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. These cables are designed to facilitate the high-density wiring required for both non-redundant and redundant RUSIO modules. When used in redundant setups, ensure that the cable length (L15) is sufficient to reach the redundant FTA pair without creating tension on the connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the L15 (15-meter) length over shorter variants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 15-meter length is ideal for applications where the I\/O modules and the field termination assemblies are located in separate enclosures or at opposite ends of a large control room, providing significant installation flexibility without requiring mid-span junctions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I identify a faulty SIC cable in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMost Honeywell Safety Manager modules will report an I\/O fault if continuity is lost. Inspect the Sub-D connector for bent pins or loose thumb screws. If the cable jacket is compromised or shows signs of chemical exposure, the cable should be replaced to maintain SIL (Safety Integrity Level) ratings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Torque \u0026amp; Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mating the Female Sub-D connector to the FTA, ensure the thumb screws are hand-tightened to prevent vibration-induced loosening. In high-vibration environments, such as near heavy rotating machinery or turbines, verify the connection periodically as part of your preventive maintenance schedule.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum bend radius of at least 10 times the cable diameter during installation. Sharp bends can cause internal conductor stress or \"cold flow\" of the insulation, which may lead to intermittent signal loss in critical safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAvoid routing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS-SICC-1011\/L15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealongside high-voltage AC power cables. Although the cable is shielded, maintaining physical separation (minimum 100 mm) reduces the risk of electromagnetic interference (EMI) affecting sensitive analog measurements from the RUSIO module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705770799467,"sku":"FS-SICC-1011\/L15","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fs-sicc-1011l15-crd0nip2ieq.jpg?v=1765952410","url":"https:\/\/www.plcprotech.com\/products\/fs-sicc-1011-l15-honeywell-safety-manager-rusio-sic-to-female-sub-d-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}