{"product_id":"ge-ds215tccag1bzz01a-mark-v-common-analog-i-o-board","title":"GE DS215TCCAG1BZZ01A Mark V Common Analog I\/O Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ecommon analog I\/O board\u003c\/strong\u003e serves as a centralized processing interface within the gas turbine control system core architecture. The \u003cstrong\u003eDS215TCCAG1BZZ01A\u003c\/strong\u003e filters, conditions, and scales multiple channels of analog field signals routing from adjacent terminal boards, including the CTBA, TBQA, and TBCA hardware arrays. This processing board accommodates a versatile spectrum of field inputs such as 4-20 mA current loops, resistance temperature detectors (RTDs), thermocouple sensor networks, and specialized turbine shaft monitoring sensors for voltage and current metrics. Conditioned process parameters are consolidated and dynamically transmitted over a dedicated internal bus to the system's core I\/O Engine and main COREBUS interface. Installed in the designated R5 core location 2, this module ensures high-integrity analog-to-digital signal conversion to maintain precise control loop variables across commercial power generation and oil transmission facilities.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEquipped with an 8-channel analog input design supporting switchable 12-bit and 16-bit resolution tracking.\u003c\/li\u003e\n\u003cli\u003eFeatures discrete current conversion tracks utilizing onboard high-accuracy burden resistors to convert 4-20 mA inputs into voltage readings.\u003c\/li\u003e\n\u003cli\u003eIntegrates dedicated hardware jumpers to independently toggle the serial RS232 maintenance interface and configure oscillator testing states.\u003c\/li\u003e\n\u003cli\u003eIncorporates multiple hardware plug blocks to accept simultaneous inputs from RTD arrays, thermocouples, and cold-junction references.\u003c\/li\u003e\n\u003cli\u003eUtilizes a highly robust communication infrastructure running on standard RS-485 balanced transmission protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpeedtronic Mark V Gas Turbine Control Platforms\u003c\/li\u003e\n\u003cli\u003eMulti-Channel RTD and Thermocouple Thermal Monitoring Arrays\u003c\/li\u003e\n\u003cli\u003eHeavy-Duty Turbine Shaft Voltage and Current Measurement Systems\u003c\/li\u003e\n\u003cli\u003e4-20 mA Remote Control Instrumentation Loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration and Rating Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS215TCCAG1BZZ01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Analog I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Analog Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage (0-10V, ±10V), 4-20 mA, RTD, Thermocouple, Shaft V\/I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage (0-10V, ±10V), 4-20 mA Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\/Output Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit \/ 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485 (Board includes J1 for serial RS232 selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Barrier Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Block \/ Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Signal Mapping\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2PL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReceives and distributes board power from the core TCPS power card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3PL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFunctions as the data bus linking TCCA, STCA, and TCCB boards to pass data to COREBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJAA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmits conditioned 4-20 mA analog output control signals to the CTBA terminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJBB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarries turbine shaft voltage, shaft current, and 4-20 mA inputs from the CTBA board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJCC \/ JDD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput channels for resistance temperature detector (RTD) lines from the TBCA board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJAR \/ JAS \/ JAT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterface connections for thermocouple and cold junction sensors from the TBQA board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitors internal power supply diagnostic alerts from the core TCPS board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment\u003c\/strong\u003e: Mount the assembly board onto standard industrial symmetric DIN rails within the R5 control panel structure. Ensure the module is clipped tightly to check against loose alignments under heavy operating vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Initialization\u003c\/strong\u003e: Configure the onboard hardware jumpers J1, JP2, and JP3 prior to powering up the system cabinet. Ensure J1 is correctly configured depending on whether the local RS232 testing port needs to be enabled or disabled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding and Wiring\u003c\/strong\u003e: Route the high-density analog ribbon cables from the external CTBA, TBQA, and TBCA panels directly to their respective matching ports (JAA, JBB, JCC, JDD, JAR\/S\/T). Maintain strict line separation from raw AC power lines to avoid low-frequency magnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Constant Parameters\u003c\/strong\u003e: Open the standard I\/O Configuration Editor platform located on the master HMI console to set up calibration thresholds, resistor tracking definitions, and unique engineering units for all connected current loops and RTD elements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695410082155,"sku":"DS215TCCAG1BZZ01A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ds215tccag1bzz01a-common-analog-i-o-board-flqqxwq05be_15d382db-e8a6-4a6b-b7ad-35cb1a9206e1.jpg?v=1766135027","url":"https:\/\/www.plcprotech.com\/products\/ge-ds215tccag1bzz01a-mark-v-common-analog-i-o-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}