{"product_id":"ge-energy-is200tsvch1a-mark-vie-servo-i-o-terminal-board","title":"GE Energy IS200TSVCH1A Mark VIe Servo I\/O Terminal Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Energy IS200TSVCH1A\u003c\/strong\u003e is a Servo Input\/Output Terminal Board designed for the \u003cstrong\u003eMark VIe\u003c\/strong\u003e Turbine Control System series. It provides interface connections for two electro-hydraulic servo valves used to actuate steam and fuel valves in turbine drive assemblies. The board accepts inputs from up to eight Linear Variable Differential Transformers (LVDTs) for valve position measurement and integrates two pulse rate signals for gas turbine fuel flow monitoring. Designed with conformal coating on its PCB assembly, the unit supports simplex, dual, and TMR control configurations and communicates with the WSVO servo driver and PSVO I\/O pack.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces with two electro-hydraulic servo valves\u003c\/li\u003e\n\u003cli\u003eSupports up to eight LVDT winding inputs for valve position feedback\u003c\/li\u003e\n\u003cli\u003eIncludes two pulse rate signal inputs (magnetic or TTL)\u003c\/li\u003e\n\u003cli\u003eProvides 28 V dc internal power supply capacity with socket J28 connections\u003c\/li\u003e\n\u003cli\u003eIncorporates a K1 trip override relay driven by the protection pack\u003c\/li\u003e\n\u003cli\u003eEquipped with conformal coating on circuit board assembly\u003c\/li\u003e\n\u003cli\u003eSupports simplex, dual, and Triple Modular Redundant (TMR) control modes\u003c\/li\u003e\n\u003cli\u003eIncludes an integrated shield bar on the left side connected to chassis ground\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas Turbine Control Systems\u003c\/li\u003e\n\u003cli\u003eSteam Turbine Control Systems\u003c\/li\u003e\n\u003cli\u003eWind Turbine Control Systems\u003c\/li\u003e\n\u003cli\u003eElectro-Hydraulic Servo Valve Management\u003c\/li\u003e\n\u003cli\u003eFuel Flow Monitoring Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOriginal Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS200TSVCH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTSVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eServo I\/O Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 barrier type terminal blocks with optional pluggability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 terminal connections per block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to #12 AWG wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLVDT Windings Input Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Rate Signal Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 inputs (magnetic or TTL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eServo Current Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 20, 40, 80, 120 mA (three coils each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLVDT Excitation Sources\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 sources (transformer isolation), 2 sources (no transformer isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Excitation Sources\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 24 V dc sources for pulse rate transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSVO I\/O pack, WSVO servo driver (Not compatible with VSVO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to 65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.02 cm x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB1 \/ TB2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain I\/O terminal blocks (24 connections each for sensors and servo valves)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB4\/3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo excitation outputs located to the left of the internal power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJ28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket for three 28 V dc power supply inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJD1 \/ JD2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal trip plugs for protection module connection \/ external trip wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJP1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eServo 1 coil current select jumper (Simplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJP4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eServo 2 coil current select jumper (Simplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJP 1-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eServo 1 coil current select jumpers (TMR system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJP 4-6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eServo 2 coil current select jumpers (TMR system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Designed for surface-mount installations inside protective enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Connection\u003c\/strong\u003e: Connect field sensors and servo valves using up to #12 AWG wiring to the two 24-terminal barrier blocks, securing each block with its two screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Terminate shield wiring to the dedicated shield terminal strips located on the left side of each terminal block, which connect directly to chassis ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Wiring\u003c\/strong\u003e: Route external trip wiring through the JD1 or JD2 connectors for integration with the protection module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Select appropriate coil currents for simplex or TMR systems via jumpers JP1 through JP6 before powering the unit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53648661152107,"sku":"IS200TSVCH1A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IS200TSVCH1A.jpg?v=1785644337","url":"https:\/\/www.plcprotech.com\/products\/ge-energy-is200tsvch1a-mark-vie-servo-i-o-terminal-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}