{"product_id":"ge-fanuc-ic695psd040-pacsystems-rx3i-dc-power-supply-module","title":"GE Fanuc IC695PSD040 PACSystems RX3i DC Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PSD040\u003c\/strong\u003e is a \u003cstrong\u003e40-Watt DC power supply module\u003c\/strong\u003e designed for use within the \u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e programmable automation controller platform. Operating from an input voltage range of 18 VDC to 30 VDC , this power supply occupies a single backplane slot and supplies power directly to the backplane. It provides three key voltage outputs to support internal module operations and external relay logic: a +5.1 VDC output, a +3.3 VDC output (used internally by IC695 series modules), and a +24 VDC relay output to power circuits on Output Relay modules.\u003c\/p\u003e\n\u003cp\u003eDesigned for non-redundant and non-increased capacity applications, only a single \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e power supply module may be installed within an RX3i Universal Backplane. If system current demands exceed the capacity of this 40-Watt supply, additional modules must be relocated to remote or expansion backplanes. The module features comprehensive diagnostic capability, enabling the CPU to log power supply faults, overtemperatures, or overload conditions directly in the CPU Fault Table.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Output Voltages:\u003c\/strong\u003e Delivers +5.1 VDC, +3.3 VDC, and +24 VDC relay power directly to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Status Indicators:\u003c\/strong\u003e Four front-panel LEDs provide immediate visual status for Power (Green\/Amber), P\/S Fault (Red), Over Temperature (Amber), and Overload (Amber).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn\/Off Switch protection:\u003c\/strong\u003e The front-panel ON\/OFF switch controls the outputs of the supply without interrupting line power. A projecting protective tab prevents accidental toggle actions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent and Thermal Protection:\u003c\/strong\u003e Incorporates electronic current limiting on the 5.1 VDC and 3.3 VDC outputs, alongside an internal fusible backup link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Overvoltage Protection:\u003c\/strong\u003e Features a user-installable bottom terminal jumper strap to link overvoltage protection devices directly to the frame ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePACSystems RX3i Controller Systems:\u003c\/strong\u003e Provides base power to CPUs and I\/O modules installed in standard universal backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Logic Modules:\u003c\/strong\u003e Supplies +24 VDC relay output power to run external circuits on Output Relay modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial DC Control Panels:\u003c\/strong\u003e Ideal for manufacturing facilities relying on 24 VDC nominal power distribution infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC695PSD040E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRX3i DC Power Supply Module, 40 Watts (Corrects previous PSD140 ID mismatch reporting error) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC698ACC701\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional Accessory Kit containing replacement BR2477A lithium battery \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Rated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStart \/ Run Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC to 30 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Watts maximum at full load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Amps, 100 milliseconds maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 Watts maximum total \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e- 5.1 VDC: 30 Watts maximum \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e- 3.3 VDC: 30 Watts maximum \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e- 5.1 VDC: 0 to 6 Amps \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e- 3.3 VDC: 0 to 9 Amps \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e- 5.1 VDC: 5.0 VDC to 5.2 VDC (5.1 VDC nominal) \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e- 3.3 VDC: 3.1 VDC to 3.5 VDC (3.3 VDC nominal) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise (All Outputs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRide-through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms (time output remains valid during source power interruption) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (De-rating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull output power is available up to at least 40 Celsius (89.6 Fahrenheit). Maximum output power above 40 Celsius is subject to thermal deratings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Amps \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Slot Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe front-facing terminal strip of the power supply is designed to accept copper conductors for field wiring:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e+\u003c\/strong\u003e \/ \u003cstrong\u003eL1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003ePositive DC Input Power Line (Accepts daisy-chaining to additional units) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e+\u003c\/strong\u003e \/ \u003cstrong\u003eL1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003ePositive DC Input Power Line (Secondary terminal for daisy-chaining) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e-\u003c\/strong\u003e \/ \u003cstrong\u003eN\u003c\/strong\u003e \/ \u003cstrong\u003eL2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNegative DC Input Power Line \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e-\u003c\/strong\u003e \/ \u003cstrong\u003eN\u003c\/strong\u003e \/ \u003cstrong\u003eL2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNegative DC Input Power Line \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Ground Icon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect connection to Frame Ground \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Ground Icon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect connection to Frame Ground \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Icon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Overvoltage protection device terminal (connected via jumper strap to Frame Ground) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Capacity:\u003c\/strong\u003e Use wire rated for 90 Celsius. Ground and power terminals accept individual 14 AWG to 22 AWG copper wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Preparation:\u003c\/strong\u003e Strip wire ends between 3\/8 inch (9 mm) and 11 mm (.433 in). Ensure the wire is fully inserted past the internal insulation stop before tightening terminal screws to prevent loose connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torques:\u003c\/strong\u003e Control terminals require a tightening torque of 9.6 to 11.5 in-lb. Input terminals require a torque of 4.4 in-lb (0.5 N-m).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Matching:\u003c\/strong\u003e When using a single external DC source to feed multiple power supplies, connection polarity must be identical across all RX3i power supplies to avoid hazardous potential differences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding:\u003c\/strong\u003e All backplanes in the system must be linked to a common system ground. Ground wires must be kept as short as possible and connected directly to the mounting panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHi-Pot Testing:\u003c\/strong\u003e To execute a high-potential test on this power supply, the overvoltage protection jumper between the bottom terminal and the frame ground terminal must be temporarily removed. Reinstall the jumper after testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Incompatibility:\u003c\/strong\u003e This module is non-isolated and must not be used with floating or positive grounded electrical systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Hazardous Locations:\u003c\/strong\u003e Suitable for Class I, Division 2, Groups A, B, C, and D hazardous locations only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695415980395,"sku":"IC695PSD040","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic695psd040-rx3i-universal-backplane-power-supply-52kktsp322d_1786ee3d-59fa-455b-a32c-b146f7821a82.jpg?v=1766135250","url":"https:\/\/www.plcprotech.com\/products\/ge-fanuc-ic695psd040-pacsystems-rx3i-dc-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}