{"product_id":"ge-fanuc-ic695psd040f-pacsystems-rx3i-power-supply-module","title":"GE Fanuc IC695PSD040F PACSystems RX3i Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PSD040F\u003c\/strong\u003e is a 40-Watt DC-to-DC power supply designed for installation in \u003cstrong\u003ePACSystems RX3i Universal Backplanes\u003c\/strong\u003e (IC695 series). Operating from an input voltage source in the range of 18 VDC to 30 VDC , this module provides three essential internal outputs: +5.1 VDC , +24 VDC relay power to supply circuits on Output Relay modules , and +3.3 VDC utilized internally by RX3i modules with IC695 catalog numbers. The \u003cstrong\u003eIC695PSD040F\u003c\/strong\u003e model specifically resolves an issue identified in previous revisions where the power supply occasionally failed to power up when installed in a 16-Slot Universal Backplane (IC695CHS016). It occupies exactly one backplane slot and features an internal diagnostic fault reporting system that communicates with the CPU to log system faults or power loss occurrences.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Capabilities:\u003c\/strong\u003e Provides three highly regulated output channels including +5.1 VDC , +24 VDC relay power , and +3.3 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Hardware ON\/OFF Switch:\u003c\/strong\u003e Equipped with a front-panel toggle switch protected by an access door to govern output delivery without interrupting the main incoming line power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Diagnostics and Status LEDs:\u003c\/strong\u003e Includes four diagnostic front-panel LEDs to indicate real-time status: Power, P\/S Fault, Over Temperature, and Overload.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection Mechanism:\u003c\/strong\u003e Features an electronic limit on the 5.1 VDC output (7 Amps) and the 3.3 VDC output (10 Amps) with continuous automatic restart attempts during an active overload state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection Option:\u003c\/strong\u003e Features a bottom-mounted screw terminal configuration with a jumper strap to frame ground for incoming overvoltage protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e backplane configuration deployments \u003c\/li\u003e\n\u003cli\u003eIndustrial control systems utilizing Output Relay modules \u003c\/li\u003e\n\u003cli\u003ePollution Degree 2 operating environments \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption\/Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC695PSD040F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 40W 24 VDC Input Power Supply Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC695PSD040CA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coated Version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC695PSD040LT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Temperature Version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC695PSD040F \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Rated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Watts maximum at full load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Amps, 100 milliseconds maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Watts maximum total of all loads (5.1 VDC: 30 Watts max; 3.3 VDC: 30 Watts max) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC: 5.0 VDC to 5.25 VDC; 3.3 VDC: 3.2 VDC to 3.465 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC: 0 to 6 Amps; 3.3 VDC: 0 to 9 Amps \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (input to backplane) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple and Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV (all outputs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms (duration outputs are maintained upon source input interruption) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Amps \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG to 22 AWG copper conductors rated 75 Celsius minimum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 Celsius (Full output power available up to 40 Celsius) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive DC Power Input \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Connection to additional daisy-chained units \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative DC Power Input \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Connection to additional daisy-chained units \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Ground Symbol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Frame Ground Connection (connect directly to mounting panel) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Ground Symbol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJumper Strap Connection for Overvoltage Protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMOV Disconnect Symbol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvervoltage Protection Device Connection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Limitation:\u003c\/strong\u003e Install only one \u003cstrong\u003eIC695PSD040F\u003c\/strong\u003e power supply in a single PACSystems RX3i Universal Backplane. It cannot be utilized in multiple power supply systems to achieve load sharing or reduncancy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Polarity:\u003c\/strong\u003e Ensure connection polarity is identical at each RX3i power supply when using the same external DC power source across multiple units to prevent equipment damage or personal injury.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Grounding:\u003c\/strong\u003e Connect each backplane to a common system ground, keeping frame ground wiring paths as short as possible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Terminal Torque:\u003c\/strong\u003e Strip individual wire ends between 9 mm and 11 mm. Insert fully into the terminal before tightening. Do not exceed the maximum terminal screw torque limit of 0.5 N-m (4.4 inch-lbs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Potential Testing:\u003c\/strong\u003e Temporarily disable overvoltage protection by removing the jumper strap from the bottom terminal prior to running a Hi-pot test. Reinstall the jumper once testing is complete.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eMarine (ABS)\u003c\/li\u003e\n\u003cli\u003eClass I, Division 2, Groups A, B, C, D \u003c\/li\u003e\n\u003cli\u003eClass I, Zone 2 \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695417717099,"sku":"IC695PSD040F","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic695psd040f-power-supply-module-khyx2dx3czc_44c9f2a9-9c8b-475b-b84b-f6d499b0c160.jpg?v=1766135302","url":"https:\/\/www.plcprotech.com\/products\/ge-fanuc-ic695psd040f-pacsystems-rx3i-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}