{"product_id":"ge-fanuc-is420ucscs2-mark-vies-safety-controller","title":"GE Fanuc IS420UCSCS2 Mark VIeS Safety controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS420UCSCS2\u003c\/strong\u003e is a high-reliability functional safety controller engineered for the GE Fanuc Mark VIeS Safety Control System. This standalone \u003cstrong\u003esafety controller\u003c\/strong\u003e features a high-performance Dual-Core 1.6 GHz AMD G-Series processor, specifically designed to execute safety critical logic for Safety Instrumented Systems (SIS), Emergency Shutdown (ESD) systems, and Burner Management Systems (BMS). It functions as the central intelligence module within a distributed control architecture, providing real-time computation, diagnostics, and deterministic control loop execution.\u003c\/p\u003e\n\u003cp\u003eEquipped with high-speed Ethernet communication capability, the \u003cstrong\u003eIS420UCSCS2\u003c\/strong\u003e safety controller interfaces seamlessly with Mark VIeS functional safety I\/O packs over redundant networks. It communicates using proprietary, safety-certified industrial communication protocols to maintain system integrity up to SIL 3 requirements. This \u003cstrong\u003esafety controller\u003c\/strong\u003e is fully certified for deployment in hazardous environments, offering robust protection, extended uptime, and complete cross-system compatibility within existing Mark VIe and Mark VIeS architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in high-speed Dual-Core 1.6 GHz AMD G-Series hardware processor for dedicated safety task execution.\u003c\/li\u003e\n\u003cli\u003eSeamless integration with Mark VIeS Safety Control functional safety I\/O networks.\u003c\/li\u003e\n\u003cli\u003eSupports high-performance industrial communication with triple-redundant or dual-redundancy options.\u003c\/li\u003e\n\u003cli\u003eCertified for installation directly within challenging industrial environments and classified hazardous locations.\u003c\/li\u003e\n\u003cli\u003eComprehensive internal runtime self-diagnostics to ensure continuous system reliability and hardware integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS)\u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown (ESD) Systems\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eCritical Fire and Gas (F\u0026amp;G) Detection Networks\u003c\/li\u003e\n\u003cli\u003eTurbine Over-speed Protection and Critical Control loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS420UCSCS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VIeS Safety Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-core, 1.6 GHz AMD G-Series Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Location Certification Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL DEMKO 20 ATEX 2359X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUS \u0026amp; Canada Class I Division 2 Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Div 2, Groups A, B, C, D, T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUS \u0026amp; Canada Class I Zone 2 Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2, AEx\/Ex nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Zone 2 Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL File Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE207685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eAll structural enclosures and DIN rails housing the controller must be connected to a low-impedance system safety ground. Implement proper cable shielding guidelines for all network communication and interface cables to mitigate Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI).\u003c\/p\u003e\n\u003ch3\u003eCooling and Ventilation\u003c\/h3\u003e\n\u003cp\u003eMaintain proper clearance surrounding the enclosure to allow natural convection cooling. Ensure that the internal enclosure temperature does not exceed the maximum operational ambient temperature rating of +70 degC.\u003c\/p\u003e\n\u003ch3\u003eHazardous Area Precautions\u003c\/h3\u003e\n\u003cp\u003eWhen deployed in Class I, Division 2 or Zone 2 locations, ensure all peripheral connections, wiring terminal assignments, and modules are fully rated for the specific classification. Do not disconnect equipment unless power has been removed or the area is verified to be non-hazardous.\u003c\/p\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed:\u003c\/strong\u003e File E207685 (Non-hazardous, Class I Div 2, Class I Zone 2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Certified:\u003c\/strong\u003e Zone 2, Group IIC (UL DEMKO 20 ATEX 2359X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUL 61010-1 \/ UL 61010-2-201\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 61010-1 \/ CSA-C22.2 No. 61010-2-201\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA-12.12.01-2015\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 213-15\u003c\/li\u003e\n\u003cli\u003eUL 60079-0 \/ UL 60079-15\u003c\/li\u003e\n\u003cli\u003eCAN-CSA-C22.2 No. 60079-0:11 \/ CAN-CSA-C22.2 No. 60079-15:12\u003c\/li\u003e\n\u003cli\u003eEN 60079-0:2012+A11:2013\u003c\/li\u003e\n\u003cli\u003eEN 60079-7:2015\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695415390571,"sku":"IS420UCSCS2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is420ucscs2-mark-vie-safety-controller-upyo5o0st20_1da94db4-828d-4642-af61-7583f951d5b2.jpg?v=1766135228","url":"https:\/\/www.plcprotech.com\/products\/ge-fanuc-is420ucscs2-mark-vies-safety-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}