{"product_id":"ge-horner-he693rtd600t-series-90-30-resistance-temperature-device-input-module","title":"GE Horner HE693RTD600T Series 90-30 Resistance Temperature Device Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHE693RTD600T\u003c\/strong\u003e is a high-precision resistance temperature device (RTD) input module developed by \u003cstrong\u003eGE Horner\u003c\/strong\u003e for the \u003cstrong\u003eSeries 90-30\u003c\/strong\u003e programmable logic controller platform. This module allows direct connection of RTD temperature sensors to the PLC without requiring external transmitters, transducers, or signal conditioning hardware. It performs all analog and digital processing directly on the module, writing formatted temperature readings in 0.5 degC or 0.5 degF increments directly to the controller %AI input table. Equipped with six independent channels, the device ensures reliable and localized temperature tracking across diverse industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSix individual channels supporting multi-point temperature sensor integration\u003c\/li\u003e\n\u003cli\u003eOnboard 16-bit integrating analog-to-digital converter for high-resolution signal processing\u003c\/li\u003e\n\u003cli\u003eBuilt-in fault protection utilizing a Zener diode clamp to safeguard internal circuitry\u003c\/li\u003e\n\u003cli\u003eHigh input impedance to preserve signal integrity over long field wiring runs\u003c\/li\u003e\n\u003cli\u003eDirect reporting of temperature values to the controller memory map without external signal conversion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time temperature monitoring in process control industries\u003c\/li\u003e\n\u003cli\u003eMachinery thermal protection systems\u003c\/li\u003e\n\u003cli\u003eMulti-channel HVAC and environmental control networks\u003c\/li\u003e\n\u003cli\u003ePower generation and distributed system thermal logging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Horner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHE693RTD600T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eResistance Temperature Device (RTD) Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Points Required\u003c\/td\u003e\n\u003ctd\u003e6 %AI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e75 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1000 Megohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Protection\u003c\/td\u003e\n\u003ctd\u003eZener Diode Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion Type\u003c\/td\u003e\n\u003ctd\u003e16-bit, Integrating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e50 Channels per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Tracking\u003c\/td\u003e\n\u003ctd\u003e0.1 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5 degC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module directly into a compatible slot of the Series 90-30 PLC rack, ensuring it is fully seated.\u003c\/li\u003e\n\u003cli\u003eConnect field sensors using shielded, twisted-pair extension wiring to provide maximum electrical noise immunity.\u003c\/li\u003e\n\u003cli\u003eGround the wiring shields at a single point only; if grounding at the module end, utilize the designated shield ground terminal points.\u003c\/li\u003e\n\u003cli\u003eRoute RTD signal cables away from high-voltage lines, motor conduits, and other significant sources of electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695417160043,"sku":"HE693RTD600T","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-he693rtd600t-rtd-temperature-module-vni2j4yhrb2.jpg?v=1766053528","url":"https:\/\/www.plcprotech.com\/products\/ge-horner-he693rtd600t-series-90-30-resistance-temperature-device-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}